Related Experiment Video
Updated: Feb 5, 2026

Seawater Sampling and Collection
Published on: June 17, 2009
VALHUDES: A protocol for validation of human papillomavirus assays and collection devices for HPV testing on
Back Ground:
Systematic reviews have concluded that hrHPV DNA testing using target-amplification tests is as accurate on vaginal self-samples as on clinician-taken specimens for the detection of cervical precancer. However, insufficient evidence is available for specific HPV assay/self-sample device combinations.
Objectives:
The VALHUDES protocol is designed as a diagnostic test accuracy study that aims to compare the clinical sensitivity and specificity of particular hrHPV assay(s) on vaginal self-samples and first-void-urine, collected in agreement with standardized protocols, with hrHPV testing on matched clinician-taken samples.
Study Design:
Five hundred enrolled women referred to a colposcopy clinic are invited to collect a first-void urine sample and one or more vaginal self-samples with particular devices before collection of a cervical sample by a clinician. Sample sets are subsequently analysed in a laboratory accredited for HPV testing. Disease verification for all enrolled patients is provided by colposcopy combined with histological assessment of biopsies.
Results:
A first VALHUDES study has started in Belgium in December 2017 with enrolment from four colposcopy centres. The following assays are foreseen to be evaluated: RealTime High Risk HPV assay (Abbott), cobas-4800 and -6800 (Roche), Onclarity (BD), Xpert HPV (Cepheid) and Anyplex II HPV HR (Seegene).
Conclusion:
Given empirical evidence that the relative accuracy of HPV-testing on self- vs clinician-samples is robust across clinical settings, the VALHUDES protocol offers a framework for validation of HPV assay/self-sample device combinations that can be translated to a primary screening setting.
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Filtration and Urine Formation
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Sampling Theorem
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....

