Updated: Feb 5, 2026

Closure of a Patent Foramen Ovale PFO: An Intervention Sequence
Published on: December 23, 2022
Frank E Corrigan1,2, Michael J Hall1, Jose Miguel Iturbe1
1Divisions of Cardiology and Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, Georgia.
This study evaluated radiation exposure for interventional echocardiographers compared to interventional cardiologists during complex heart procedures. Researchers found that while specialized shielding effectively lowers body and eye radiation for echocardiographers, their hands remain at higher risk during specific imaging techniques. The findings highlight the need for improved safety designs in procedural suites.
Area of Science:
Background:
No prior work had resolved the precise radiation risks faced by interventional echocardiographers during complex structural heart procedures. That uncertainty drove the need for systematic monitoring of exposure levels. Prior research has shown that interventional cardiologists often receive significant ionizing radiation during these high-complexity tasks. This gap motivated a comparison between the primary physician and the imaging specialist. It was already known that structural heart interventions rely heavily on real-time imaging guidance. However, the specific safety profile for the echocardiography team remained poorly defined. This study addresses the urgent requirement for objective data regarding occupational hazards. Researchers aimed to quantify the differences in radiation burden between the two distinct clinical roles.
Purpose Of The Study:
The aim of this investigation was to evaluate the effectiveness of radiation protection for interventional echocardiographers during complex heart procedures. Researchers sought to compare these exposure levels against those experienced by interventional cardiologists. The study addressed the growing concern regarding increased radiation risks for imaging specialists in modern clinical suites. This motivation stemmed from the expanding complexity of structural heart interventions and the resulting reliance on imaging. No prior work had systematically quantified the radiation burden for the echocardiography team in this specific context. The investigators intended to identify whether current shielding measures provide adequate protection for all staff members. They also aimed to determine if specific imaging techniques contribute to higher localized radiation doses. This research provides a necessary assessment of occupational safety in high-exposure medical environments.
Main Methods:
The review approach involved monitoring 32 distinct structural heart procedures to evaluate occupational radiation hazards. Investigators tracked 19 transcatheter aortic valve replacements alongside 13 other cardiac repair cases. The team utilized both transesophageal and transthoracic imaging modalities to guide these interventions. Staff members wore multiple dosimeters on various body locations to capture precise dose measurements. These sensors recorded radiation levels for the total body, the lens of the eye, and the hands. During every case, the imaging specialists employed dedicated radiation shielding equipment. Researchers compared the recorded doses between the primary cardiologist and the echocardiographer. This systematic assessment provided a clear picture of the radiation burden for each professional role.
Main Results:
Key findings from the literature indicate that mean radiation doses were generally higher for the primary cardiologist than for the primary echocardiographer. The cardiologist received 99, 222, and 378 μSv for the body, lens, and hands, respectively. In contrast, the echocardiographer recorded 48, 52, and 416 μSv for the same anatomical sites. Dedicated shielding successfully reduced body and lens exposure for the imaging team during both imaging modalities. However, the hand equivalent dose remained notably higher for the echocardiographer during transesophageal procedures. Specifically, the cardiologist received 294 μSv compared to 676 μSv for the echocardiographer in these instances. The use of protective drapes during transthoracic valve replacements lowered the cardiologist's dose but showed no effect on the imaging specialist. These results underscore the complex nature of radiation distribution in the clinical environment.
Conclusions:
The authors propose that dedicated shielding effectively mitigates radiation risks to the body and eyes of echocardiographers. Their findings suggest that interventional cardiologists generally experience higher total body and ocular exposure. The researchers indicate that hand radiation remains a significant concern for echocardiographers during specific imaging procedures. This synthesis implies that current protective measures do not fully eliminate risks to the hands. The study highlights that standard drapes may benefit cardiologists without providing similar protection to the imaging team. These results suggest that procedural suite design requires further optimization to enhance safety. The investigators conclude that ongoing vigilance is necessary to manage occupational exposure effectively. Their work emphasizes the need for tailored strategies to protect all members of the clinical team.
The researchers observed that echocardiographers received lower body and lens doses than cardiologists, yet experienced higher hand exposure. Specifically, hand doses reached 676 μSv for echocardiographers versus 294 μSv for cardiologists during procedures requiring transesophageal imaging.
The team utilized multiple dosimeters placed on various body sites to track ionizing radiation. These sensors measured exposure to the total body, the lens of the eye, and the hands throughout each clinical case.
The authors note that hand exposure is higher for echocardiographers specifically during transesophageal echocardiography. This technical necessity arises because the imaging probe requires manual manipulation in closer proximity to the radiation source compared to transthoracic methods.
The study monitored 32 procedures, including 19 transcatheter aortic valve replacements and 13 other structural heart repairs. These data points allowed for a direct comparison of radiation levels across different clinical scenarios.
The investigators measured radiation in microsieverts (μSv). They recorded mean doses for the primary cardiologist at 99, 222, and 378 μSv, while the primary echocardiographer received 48, 52, and 416 μSv for the body, lens, and hands, respectively.
The researchers propose that further optimization of structural suite design and shielding is necessary. They suggest that current protective strategies are insufficient for the hands and require advancements to improve safety for the entire team.