Particle Image Velocimetry Investigation of Hemodynamics via Aortic Phantom
Published on: February 25, 2022
Fluid Dynamic Characterization of Transcatheter Aortic Valves Using Particle Image Velocimetry
Mohammed Barakat1, Danny Dvir2, Ali N Azadani1
1Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA.
Abstract:
Transcatheter aortic valves provide superior systolic hemodynamic performance in terms of valvular pressure gradient and effective orifice area compared with equivalent size surgical bioprostheses. However, in depth investigation of the flow field structures is of interest to examine the flow field characteristics and provide experimental evidence necessary for validation of computational models. The goal of this study was to compare flow field characteristics of the three most commonly used transcatheter and surgical valves using phase-locked particle image velocimetry (PIV). 26-mm Edwards SAPIEN 3, 26-mm Medtronic CoreValve, and 25-mm Carpentier-Edwards PERIMOUNT Magna were examined in a pulse duplicator with input parameters matching ISO-5840, that is, heart rate of 70 beats/min, cardiac output of 5 L/min, and mean aortic pressure of 100 mm Hg. A 2D PIV system was used to obtain flow velocity and viscous shear stress fields during the entire cardiac cycle. In vitro testing showed that the mean transvalvular pressure gradient was lowest for SAPIEN 3, followed by CoreValve, and PERIMOUNT Magna surgical bioprosthesis. In addition, the viscous shear stress magnitude within the jet boundary layer was higher in PERIMOUNT Magna than CoreValve and SAPIEN 3 at the peak of the flow. However, the measured shear stress values were below the known threshold for platelet activation and red blood damage. Therefore, shear-induced platelet activation is unlikely to take place during systole in the three bioprosthetic heart valves. The PIV measurements can be used for verification and validation of computational simulations.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Subatomic Particles
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
The Fluid Mosaic Model
Mitral Valve Prolapse I: Introduction
Dynamic Equilibrium