Related Experiment Video
Updated: Feb 5, 2026

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Glyphosate Determination by Coupling an Immuno-Magnetic Assay with Electrochemical Sensors
Francesca Bettazzi1, Aline Romero Natale2, Eduardo Torres3
1Dipartimento di Chimica, Università degli Studi di Firenze, Via della Lastruccia 3, 50019 Sesto Fiorentino (Fi), Italy. francesca.bettazzi@unifi.it.
Abstract:
Glyphosate (N-(phosphonomethyl)glycine) is the most frequently used broad-spectrum herbicide worldwide. Its mechanism of action is based on the inhibition of an enzyme that is essential to plant growth. Its intensive use has caused global contamination to occur, which has not only affected the ecosystems, but even food and other objects of common use. Thus, there is a pronounced need for developing analytical methods for glyphosate determination in different matrices. Here, an electrochemical competitive immunoassay, based on the use of antibody-modified magnetic particles, has been developed. Tetramethylbenzidine (TMB) has been used as an enzymatic substrate. The extent of the affinity reaction has been achieved by monitoring the current value, due to the reduction of the enzymatic product. A disposable screen-printed electrochemical cell has been used. The calibration curve has been recorded in the 0⁻10,000 ng/L concentration range, with a detection limit of 5 ng/L and quantification limit of 30 ng/L. The electrochemical immunoassay has also been applied to the analysis of spiked beer samples.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
G-protein Coupled Receptors
Spin–Spin Coupling: One-Bond Coupling
Interfacial Electrochemical Methods: Overview