Related Experiment Video
Updated: Feb 5, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Ultrasound-guided Placement of Single-lumen Peripheral Intravenous Catheters in the Internal Jugular Vein
Tony Zitek1,2,3, Elizabeth Busby1, Heather Hudson2
1University of Nevada, Las Vegas School of Medicine, Department of Emergency Medicine, Las Vegas, Nevada.
Introduction:
The peripheral internal jugular (IJ), also called the "easy IJ," is an alternative to peripheral venous access reserved for patients with difficult intravenous (IV) access. The procedure involves placing a single-lumen catheter in the IJ vein under ultrasound (US) guidance. As this technique is relatively new, the details regarding the ease of the procedure, how exactly it should be performed, and the safety of the procedure are uncertain. Our primary objective was to determine the success rate for peripheral IJ placement. Secondarily, we evaluated the time needed to complete the procedure and assessed for complications.
Methods:
This was a prospective, single-center study of US-guided peripheral IJ placement using a 2.5-inch, 18-gauge catheter on a convenience sample of patients with at least two unsuccessful attempts at peripheral IV placement by nursing staff. Peripheral IJ lines were placed by emergency medicine (EM) attending physicians and EM residents who had completed at least five IJ central lines. All physicians who placed lines for the study watched a 15-minute lecture about peripheral IJ technique. A research assistant monitored each line to assess for complications until the patient was discharged.
Results:
We successfully placed a peripheral IJ in 34 of 35 enrolled patients (97.1%). The median number of attempts required for successful cannulation was one (interquartile range (IQR): 1 to 2). The median time to successful line placement was 3 minutes and 6 seconds (IQR: 59 seconds to 4 minutes and 14 seconds). Two lines failed after placement, and one of the 34 successfully placed peripheral IJ lines (2.9%) had a complication - a local hematoma. There were, however, no arterial punctures or pneumothoraces. Although only eight of 34 lines were placed using sterile attire, there were no line infections.
Conclusion:
Our research adds to the growing body of evidence supporting US-guided peripheral internal jugular access as a safe and convenient procedure alternative for patients who have difficult IV access.
More Related Videos
13:58A Rabbit Model of Durable Transgene Expression in Jugular Vein to Common Carotid Artery Interposition Grafts
Published on: September 10, 2018
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Related Concept Videos
Internal Energy
Internal Energy
Internal Receptors
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...