Wireless video transmission into the MRI magnet room: implementation and evaluation at 1.5T, 3T and 7T
Bennet Hensen1,2, Urte Kägebein2,3, Marcel Gutberlet3
1Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany, Phone: +49511 532 3421.
Abstract:
Purpose To analyze the interference between a wireless high definition multimedia interface (WHDMI) and magnetic resonance imaging (MRI) image quality at 1.5T, 3T and 7T. Materials and methods A wireless video transmission system (WVTS) consisting of a WHDMI and a projector was used to transmit and display a video stream into the magnet room. MR image quality was analyzed at 1.5T, 3T and 7T. Signal-to-noise-ratio (SNR¯) $(\overline {{\rm{SNR}}} )$ and radio frequency (RF)-noise spectrum were measured at three transmitter positions (A: inside the cabin, B: in front of the waveguide and C: in the control room). WVTS system functionality tests included measurements of reliability, delay and image quality. Results With the WVTS mean SNR¯ $\overline {{\rm{SNR}}} $ values significantly decreased in comparison to the reference for all positions and fieldstrenghts, while the spectra's baseline is elevated at 1.5T and 3T. Peaks related to continuous wave interferences are apparent at all field strenghts. For WHDMI alone mean SNR¯ $\overline {{\rm{SNR}}} $ values were stable without significant differences to the reference. No elevation of the spectra's baseline could be observed. Functionality measurements confirmed high connection reliability with stable image quality and no delays for all field strengths. Conclusion We conclude that wireless transmission of video streams into the MRI magnet room is feasible at all field strengths without hampering image quality.
More Related Videos
11:29Real-time Video Projection in an MRI for Characterization of Neural Correlates Associated with Mirror Therapy for Phantom Limb Pain
Published on: April 20, 2019
08:57Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT
Published on: March 3, 2023
Related Concept Videos
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Design of Transmission Shafts
Transmission Line Design Considerations
Transmission Shafts: Problem Solving
Next, use bending moment diagrams for the shaft to...
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from...