Approaches to Cough Peak Flow Measurement With Duchenne Muscular Dystrophy
Kazuto Kikuchi1, Masahiro Satake2, Yusuke Kimoto2
1Department of Rehabilitation, Akita National Hospital, Yurihonjo City, Japan. riha1@akitahp.jp.
Background:
Manually-assisted coughing and mechanical insufflation-exsufflation (MI-E) are commonly used in patients with Duchenne muscular dystrophy (DMD). Few studies have compared cough peak flow (CPF) with manually-assisted coughing to other methods, such as MI-E + manually-assisted coughing. In addition, few studies have reported the reliability of the measured CPF values. This study aimed to compare CPF with different cough-assistance methods and to examine the reliability of CPF data.
Methods:
The study included 12 subjects with DMD (mean age, 34 ± 8 y). CPF, CPF + manually-assisted coughing (assisted CPF), maximum insufflation capacity (MIC) + CPF (MIC-CPF), MIC + manually-assisted coughing (MIC+assisted CPF), MI-E (MI-E-CPF), and MI-E + assisted CPF were measured. A spirometer was used to compare CPF measurements obtained with each of the cough-assist techniques. The reliability of the measured CPF values was analyzed using Bland-Altman analysis.
Results:
CPF was 59 ± 34 L/min, assisted CPF was 113 ± 32 L/min, MIC-CPF was 170 ± 30 L/min, MIC+assisted CPF was 224 ± 62 L/min, MI-E-CPF was 199 ± 40 L/min, and MI-E + assisted CPF was 240 ± 38 L/min. A fixed and proportional bias was found in the CPF measurements made with the peak flow meter and the spirometer. The average 95% CI in the difference between peak flow meter, MI-E, and CPF obtained using the spirometer were -7.45 to -1.95 and -1.45 to 4.95, respectively. Test for correlation was r = 0.54 (P < .001) for CPF (peak flow meter) and CPF (spirometer) and r = 0.17 (P = .17) in CPF (MI-E) and CPF (spirometer), respectively.
Conclusion:
MI-E + assisted CPF was the highest. The CPF measured with the peak flow meter suggested underestimation.
Related Concept Videos
Satellite Stem Cells and Muscular Dystrophy
The Muscular System
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
IR Spectrum Peak Broadening: Hydrogen Bonding
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular...
IR Spectrum Peak Intensity: Dipole Moment