Related Experiment Video
Updated: Feb 5, 2026

06:53
Modeling Primary Bone Tumors and Bone Metastasis with Solid Tumor Graft Implantation into Bone
Published on: September 9, 2020
3.3K
A simple method for bone graft insertion during Schatzker II and III plateau fixation
Donald Adams1, Jay N Patel1, Vineet Tyagi2
1Division of Orthopaedic Trauma and Adult Reconstruction, Department of Orthopaedic Surgery, Jersey City Medical Center - RWJBarnabas Health, 355 Grand Street, Jersey City, NJ, 07302, USA.
Summary
A modified Seldinger technique simplifies bone grafting for tibial plateau fractures. This method improves accuracy and ease when filling metaphyseal defects and supporting subchondral bone.
Area of Science:
- Orthopedic surgery
- Traumatology
- Bone grafting techniques
Background:
- Schatzker type II and III tibial plateau fractures often require bone grafting for metaphyseal defects and subchondral support.
- Current methods for graft insertion can be technically demanding, especially when working against gravity through small portals.
Observation:
- Accurate placement of bone graft material is crucial for successful fracture fixation and healing.
- Challenges include directing the graft precisely and achieving adequate density within the defect.
Findings:
- A modified technique using a 3-mL syringe, bone tamps, and the Seldinger technique was developed.
- This approach simplifies the procedure, enhancing accuracy and efficiency for bone graft delivery.
Implications:
- This method offers a more manageable solution for surgeons performing bone grafting in complex tibial plateau fractures.
- Improved graft placement can lead to better patient outcomes and reduced surgical complexity.
Related Concept Videos
Methods of Documentation III: PIE
2.1K
Problem-intervention-evaluation (PIE) is a systematic approach to documentation used in healthcare settings for clinical decision-making and patient care planning. It is a structured approach to organizing patient data based on problems, interventions, and evaluations. Here's a breakdown of its key features and considerations:
2.1K
Fixation and Sectioning
8.0K
Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens.
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
8.0K
Carbon-dioxide Fixation
716
Carbon dioxide fixation in prokaryotes enables the assimilation of inorganic carbon into organic molecules, supporting biosynthetic pathways, sustaining ecosystems, and contributing to the global carbon cycle. It also has industrial applications in carbon capture and bioproduct synthesis. Autotrophic organisms rely on this process to utilize CO₂ as a carbon source in diverse environments.The Calvin CycleThe Calvin cycle is the most widespread carbon fixation mechanism, primarily used by...
716
Simple Pendulum
8.1K
A simple pendulum consists of a small diameter ball suspended from a string, which has negligible mass but is strong enough to not stretch. In our daily life, pendulums have many uses, such as in clocks, on a swing set, and on a sinker on a fishing line.
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...
8.1K
Simple Trusses
2.9K
A truss is a structural framework consisting of slender members connected at joints, designed to support external loads while minimizing material usage and weight. Simple trusses are a type of planar truss where all members lie within a single two-dimensional plane.
The most basic planar truss is a simple truss with three members arranged in a triangular formation. This triangular truss is inherently stable and rigid due to its geometry, making it an ideal starting point for creating more...
The most basic planar truss is a simple truss with three members arranged in a triangular formation. This triangular truss is inherently stable and rigid due to its geometry, making it an ideal starting point for creating more...
2.9K
Torts III
1.1K
Types of Quasi-intentional Torts in Healthcare
Quasi-intentional torts in healthcare involve acts where intent is not directed to harm an individual but results in harm due to careless or reckless speech.
Quasi-intentional torts in healthcare involve acts where intent is not directed to harm an individual but results in harm due to careless or reckless speech.
1.1K

