Related Experiment Video
Updated: Aug 14, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Physics-Informed Reconstruction of Transmural Myocardial Deformation from 3D Echocardiography: Validation Against
Satya Prakash Pradhan1, Arash Yavari2,3, Issac D Lindley4
1Department of Biomedical Engineering, Samueli School of Engineering, University of California, Irvine, CA, 92697-2715, USA.
Purpose:
Quantitative assessment of myocardial deformation is increasingly important in clinical cardiology, yet conventional two-dimensional (2D) echocardiography and standard three-dimensional (3D) approaches remain limited by out-of-plane motion and incomplete characterization of transmural mechanics. To address these limitations, we introduce a physics-informed framework for 3D echocardiography that reconstructs the full finite strain tensor across the entire myocardial wall. As an initial methodological study, we demonstrate the framework and validate it against cardiac magnetic resonance in a small cohort.
Methods:
Endocardial and epicardial surfaces were segmented from 3D echocardiographic datasets and tracked throughout the cardiac cycle using speckle-tracking techniques. An optimization framework with a soft volumetric penalty was implemented, permitting volume change at finite cost while maintaining tracking fidelity and geometric smoothness. The resulting deformation field enabled reconstruction of the complete 3D strain tensor. Global strain measurements derived from the method were validated against cardiac magnetic resonance (CMR) measurements obtained in two subjects.
Results:
Global longitudinal and circumferential strain values obtained from the proposed framework showed strong agreement with CMR measurements. The optimization procedure also demonstrated robustness to segmentation variability and reduced errors associated with epicardial tracking. Beyond conventional strain indices, the method enabled reconstruction of spatially resolved principal strain fields throughout the ventricular wall, revealing physiologically consistent transmural gradients and contraction patterns.
Conclusion:
Physics-informed integration of speckle tracking with biomechanical constraints enables robust reconstruction of 3D myocardial deformation from echocardiography. This framework provides a comprehensive and physically consistent characterization of myocardial mechanics from widely available 3D echocardiographic data. These initial results support the feasibility of the proposed framework and motivate future evaluation in larger, more diverse patient cohorts to establish its clinical reliability.