Related Experiment Video
Updated: Feb 5, 2026

Ultrasonic Fatigue Testing in the Tension-Compression Mode
Published on: March 7, 2018
Sex- and Mode-specific Responses to Eccentric Muscle Fatigue
Ethan C Hill1, Terry J Housh1, Cory M Smith1
1University of Nebraska-Lincoln, Nutrition and Health Sciences, Lincoln, United States.
Abstract:
The primary purpose of the present investigation was to examine sex-related differences as a result of fatiguing eccentric muscle actions on torque, muscle blood flow, electromyography, and mechanomyography. Eighteen men and 18 women performed peak torque trials prior to (pretest), immediately after (posttest), and 5-min after (recovery) completing 50 submaximal (60% of eccentric peak torque), eccentric, isokinetic (180°·s -1) muscle actions of the elbow flexors. Electromyographic and mechanomyographic responses were simultaneously recorded from the biceps brachii muscle, and muscle blood flow was measured at pretest, posttest and recovery. There were sex- and mode-specific responses for torque, but there were no sex-specific muscle blood flow or neuromuscular responses. From pretest to posttest, torque decreased (80.0-88.2% of pretest) for both the men and women. At recovery concentric peak torque recovered to a greater extent in women (95.0% of pretest) than men (88.0% of pretest), while eccentric peak torque recovered to a greater extent in men (88.9% of pretest) than women (86.9% of pretest). The sex-specific torque responses were not associated with different motor control strategies or differences in the occlusion of muscle blood flow between the men and women. For both men and women, eccentric fatiguing exercise is manifested similarly during isometric muscle actions, but not during eccentric and concentric muscle actions.
More Related Videos
07:30Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
14:10Isometric and Eccentric Force Generation Assessment of Skeletal Muscles Isolated from Murine Models of Muscular Dystrophies
Published on: January 31, 2013
Related Concept Videos
Muscle Recovery and Fatigue
Eccentric Loading
Eccentricity of an Ellipse
Fatigue
Design Example: Frog Muscle Response
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...