Trans-catheter paravalvular leak closure: a single-centre experience

Richard Tanner1, Saber Hassan1,2, Nicola Ryan1,3

  • 1Department of Cardiology, Mater Misericordiae University Hospital, Eccles Street, Dublin 7, Ireland.

Summary

Percutaneous closure of paravalvular leak (PVL) is a safe alternative to surgery, with 86% clinical success. This minimally invasive approach is particularly effective for patients with heart failure (HF).

Related Concept Videos

Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.3K
What is an Experiment?01:12

What is an Experiment?

An experiment is a planned activity carried out under controlled conditions. The purpose of an experiment is to investigate the relationship between two variables. When one variable causes change in another, we call the first variable the explanatory or independent variable. The affected variable is called the response or dependent variable. In a randomized experiment, the researcher manipulates values of the explanatory variable and measures the resulting changes in the response variable. The...
18.8K
Disubstituted Cyclohexanes: cis-trans Isomerism02:37

Disubstituted Cyclohexanes: cis-trans Isomerism

Depending upon the different spatial orientation of the substituents, the disubstituted cycloalkanes exhibit two types of stereoisomers. The cis isomers have the substituents on the same side of the ring, whereas the trans isomers have the substituents on the opposite sides. These stereoisomers exhibit different physical properties and cannot be interconverted without breaking the carbon-carbon bonds.
In cyclohexane, the substituents can occupy different positions generating distinct isomers....
14.2K
Thomson's e/m Experiment01:19

Thomson's e/m Experiment

In a beam of charged particles created by a heated cathode, the particles move at different speeds. However, many applications need a beam with uniform particle speeds. An arrangement known as a velocity selector uses electric and magnetic fields to pick particles with a particular speed from the beam.
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
6.8K
Controls in Experiments01:13

Controls in Experiments

When conducting an experiment, it is crucial to have control to reduce bias and accurately measure the dependent variables. It also marks the results more reliable. Controls are elements in an experiment that have the same characteristics as the treatment groups but are not affected by the independent variable. By sorting these data into control and experimental conditions, the relationship between the dependent and independent variables can be drawn. A randomized experiment always includes a...
17.6K
Randomized Experiments01:13

Randomized Experiments

The randomization process involves assigning study participants randomly to experimental or control groups based on their probability of being equally assigned. Randomization is meant to eliminate selection bias and balance known and unknown confounding factors so that the control group is similar to the treatment group as much as possible. A computer program and a random number generator can be used to assign participants to groups in a way that minimizes bias.
Simple randomization
Simple...
9.1K