Introduction:
While NASA requires that commercial spaceflight vehicles provide onboard emergency oxygen supplies for crew, there are currently no requirements in place regarding thermal constraints of delivered gas. The question has been raised whether or not onboard emergency oxygen supplies must be warmed prior to administration to the crew, as inclusion of warming capabilities will increase the complexity and mass of life support systems in the vehicle. We sought to identify the risk of various inhaled oxygen temperatures and resultant pulmonary inflammatory response in potentially injured crewmembers.
Methods:
A systematic review of published literature was conducted concerning thermal regulation of inhaled gases, reactive airway response, and inflammatory reactions. In particular, we sought literature that correlated inhaled gas temperature to airway response to identify a temperature threshold that would avoid deleterious sequelae.
Results:
Cold air inhalation can induce acute bronchoconstriction, increased respiratory rate, and associated dyspnea and hypoxia. Physiological response to cold air varies between healthy lungs and injured tissues, and increased inflammation is associated with increasing airway reactivity. Most studies suggest that inhaled gas temperatures below 10°C may induce deleterious physiological sequelae.
Discussion:
Best practices would include maintenance of inhaled gas temperatures to >10°C to avoid poor physiological response, preferably as close to physiological norms as possible. Given that inhaled gas temperature may be altered by transit through an oxygen delivery system, measurement of actual delivered gas temperature should occur at the point of crewmember inhalation.Pattarini JM, Blue RS, Alexander DJ. Thermal regulation of emergency oxygen supplies in commercial space vehicles. Aerosp Med Hum Perform. 2018; 89(10):918-922.
Related Concept Videos
Regulation of Angiogenesis and Blood Supply
Emerging Adulthood
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
State Space Representation
Consider an RLC circuit, a...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Introduction Cardiac Emergencies