Related Experiment Video
Updated: Feb 5, 2026

Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
Published on: July 28, 2013
Automated motion-artifact correction in an OCTA image using tensor voting approach
Ang Li1, Guang Zeng, Congwu Du1
1Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York 1194-5281, USA.
Abstract:
Optical coherence tomography angiography (OCTA) is a promising tool for imaging subsurface microvascular networks owing to its micron-level resolution and high sensitivity. However, it is not uncommon that OCTA imaging suffers from strip artifacts induced by tissue motion. Although various algorithms for motion correction have been reported, a method that enables motion correction on a single en face OCTA image remains a challenge. In this study, we propose a motion correction approach based on microvasculature detection and broken gap filling. Unlike previous methods using registration to restore disturbed vasculature during motion artifact removal, tensor voting is performed in an individual projected image to connect the broken vasculature. Both simulation and in vivo 3D OCTA imaging of the mouse bladder are performed to validate the effectiveness of this method. A comparison of in vivo images before and after motion correction shows that our method effectively corrects tissue motion artifacts while preserving the continuity of vasculature network. Furthermore, in vivo results of this technique are presented to demonstrate its utility for imaging tumor angiogenesis in the mouse bladder.
More Related Videos
08:24Experimental Assessment of Mouse Sociability Using an Automated Image Processing Approach
Published on: May 15, 2016
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
Related Concept Videos
Inertia Tensor
The diagonal components of the inertia tensor matrix represent the moments of inertia concerning the principal axes of the object. These primary axes are defined as the axes where the object experiences the least...
Distance Corrections
Power Factor Correction
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
NMR Spectrometers: Resolution and Error Correction
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...