Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

734
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
734
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

473
Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
473
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.9K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.9K
Production Efficiency01:01

Production Efficiency

18.4K
Net production efficiency (NPE) is the efficiency at which organisms assimilate energy into biomass for the next trophic level. Due to low metabolic rates and less energy spent on thermoregulatory processes, the NPE of ectotherms (cold-blooded animals) is 10 times higher than endotherms (warm-blooded animals).
18.4K
Trophic Efficiency00:46

Trophic Efficiency

25.2K
Trophic level transfer efficiency (TLTE) is a measure of the total energy transfer from one trophic level to the next. Due to extensive energy loss as metabolic heat, an average of only 10% of the original energy obtained is passed on to the next level. This pattern of energy loss severely limits the possible number of trophic levels in a food chain.
25.2K
Efficiency of The Carnot Cycle01:16

Efficiency of The Carnot Cycle

3.7K
The hypothetical Carnot cycle consists of an ideal gas subjected to two isothermal and two adiabatic processes. Since the internal energy of an ideal gas depends only on its temperature, which is the same before and after the completion of the Carnot cycle, there is no change in its internal energy. Hence, using the first law of thermodynamics, the total heat exchanged by the ideal gas equals the total work done. Thus, we can quantify the efficiency of the Carnot cycle via the heat exchanged...
3.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Sex- and Age-Related Differences in Physiological [<sup>18</sup>F]FDOPA Uptake on Long Axial Field-of-View PET/CT Imaging.

Bioengineering (Basel, Switzerland)·2026
Same author

Comparison of physical approaches to inter-crystal scattering in a staggered-layer scintillation PET detector: a simulation study.

Physics in medicine and biology·2026
Same author

[<sup>89</sup>Zr]bevacizumab PET/CT imaging of vestibular schwannomas for the prediction of bevacizumab treatment effect in patients with symptomatic <i>NF2</i>-related schwannomatosis: a study protocol for a phase II single centre, prospective, feasibility trial.

BMJ open·2026
Same author

A phantom study to achieve comparable <sup>124</sup>I PET recovery and address scanner variability for dosimetry purposes in (re)differentiated thyroid cancer.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same author

Interpretable Machine Learning Model for Survival Prediction in Pediatric Adrenocortical Tumors.

Journal of the Endocrine Society·2026
Same author

Artificial Intelligence and Machine Learning in Pediatric Endocrine Tumors: Opportunities, Pitfalls, and a Roadmap for Trustworthy Clinical Translation.

Biomedicines·2026

Related Experiment Video

Updated: Feb 5, 2026

Computational Reconstruction of Pancreatic Islets as a Tool for Structural and Functional Analysis
07:58

Computational Reconstruction of Pancreatic Islets as a Tool for Structural and Functional Analysis

Published on: March 9, 2022

1.9K

SMART (SiMulAtion and ReconsTruction) PET: an efficient PET simulation-reconstruction tool.

Elisabeth Pfaehler1, Johan R De Jong1, Rudi A J O Dierckx1

  • 1Departments of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.

EJNMMI Physics
|September 19, 2018
PubMed
Summary
This summary is machine-generated.

A new PET simulation tool, SMART-PET, enables fast and easy generation of 3D PET images with time of flight (TOF) and resolution modeling (RM). This validated tool produces images comparable to real phantom data, aiding PET research.

Keywords:
18F-FDG PET/CTAnalytical simulationImage reconstructionPET simulation

More Related Videos

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
10:02

Whole-body PET/MRI of Pediatric Patients: The Details That Matter

Published on: December 19, 2017

15.3K
MRI and PET in Mouse Models of Myocardial Infarction
10:46

MRI and PET in Mouse Models of Myocardial Infarction

Published on: December 19, 2013

12.4K

Related Experiment Videos

Last Updated: Feb 5, 2026

Computational Reconstruction of Pancreatic Islets as a Tool for Structural and Functional Analysis
07:58

Computational Reconstruction of Pancreatic Islets as a Tool for Structural and Functional Analysis

Published on: March 9, 2022

1.9K
Whole-body PET/MRI of Pediatric Patients: The Details That Matter
10:02

Whole-body PET/MRI of Pediatric Patients: The Details That Matter

Published on: December 19, 2017

15.3K
MRI and PET in Mouse Models of Myocardial Infarction
10:46

MRI and PET in Mouse Models of Myocardial Infarction

Published on: December 19, 2013

12.4K

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Computational Science

Background:

  • Positron-emission tomography (PET) simulators are crucial for developing and evaluating segmentation methods and quantitative uptake metrics.
  • Existing PET simulation tools are often computationally intensive (Monte Carlo) or lack advanced features like time of flight (TOF) and resolution modeling (RM).

Purpose of the Study:

  • To develop and validate a fast, user-friendly PET simulation-reconstruction package, SMART-PET, incorporating both TOF and RM.
  • To provide a tool that allows customization of acquisition and reconstruction parameters for PET imaging.

Main Methods:

  • Developed SMART-PET, a package for rapid 3D PET image generation using activity and CT/attenuation maps as input.
  • Enabled adjustable parameters including TOF/RM reconstruction, noise levels, scan duration, and spatial shifts.
  • Validated SMART-PET by comparing simulated data with real scan data from the NEMA NU 2 image quality phantom.

Main Results:

  • SMART-PET generated images comparable to actual phantom data.
  • Image characteristics (noise, recovery coefficients) of simulated and real PET images showed similar variations with reconstruction protocols and noise levels.
  • Recovery coefficients for spheres agreed within 0.3-11% between simulated and actual phantom data.

Conclusions:

  • SMART-PET offers a rapid and accessible method for simulating PET data.
  • The tool allows flexible adjustment of acquisition and reconstruction settings, including RM and TOF.
  • Simulated images exhibit characteristics similar to those observed in real phantom data, confirming its utility.