Related Experiment Video
Updated: Feb 5, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
Shear Bond Strength of Different CAD/CAM Ceramics: Acid vs Er:YAG Laser Etching
Yepo Hou1, Renze Shen2, Luyuan Chen1
11 Department of Stomatology, Nanfang Hospital of Southern Medical University , Guangzhou, China .
Objective:
To evaluate whether Er:YAG laser etching could be an alternative surface treatment to hydrofluoric (HF) acid etching.
Background:
Surface treatment is important to bonding properties and utility times of computer aided design/computer aided manufacture (CAD/CAM) dental ceramics. The traditional method of HF acid etching is harmful to humans if not handled properly.
Materials And Methods:
Four different CAD/CAM ceramics (Vita Mark II, IPS Empress CAD, IPS e.max CAD, and Vita Enamic) were cut into 72 blocks and divided into 6 groups according to different surface treatments (n = 12): Group A: no treatment; Group B: HF acid; and Group C to F: different Er:YAG laser power settings (300, 400, 500, and 600 mJ). Ten blocks of each group were measured for shear bond strength (SBS) and the failure modes were evaluated; the rest blocks were observed by scanning electronic microscopy (SEM).
Results:
HF acid etching resulted in the highest SBS for Vita Mark II, IPS Empress CAD, and Vita Enamic; however, the difference was not statistically significant (p > 0.05) compared to the second highest group of laser with 600 mJ in IPS Empress CAD. For IPS e.max CAD, the highest SBS was obtained from laser group with 400 mJ. The SBS results were consistent with failure modes and surface characterizations in SEM images.
Conclusions:
Our results showed that Er:YAG laser had little impact on Vita Mark II and Vita Enamic; but proper power settings could be an alternative surface treatment to HF acid etching (600 mJ for IPS Empress CAD and 400 mJ for IPS e.max CAD).
More Related Videos
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Bonding and Strength of Aggregate
Relative Strengths of Conjugate Acid-Base Pairs
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Acid and Bases: Ka, pKa, and Relative Strengths
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...

