Related Experiment Video
Updated: Feb 5, 2026

High-Throughput Analysis of Non-Photochemical Quenching in Crops Using Pulse Amplitude Modulated Chlorophyll Fluorometry
Published on: July 6, 2022
Innovative Multi-Site Photoplethysmography Analysis for Quantifying Pulse Amplitude and Timing Variability
Michael Bentham1, Gerard Stansby2, John Allen3
1Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne NE2 4HH, UK. m.bentham@ncl.ac.uk.
Abstract:
Photoplethysmography (PPG) is a simple-to-perform vascular optics measurement technique that can detect blood volume changes in the microvascular bed of tissue. Beat-to-beat analysis of the PPG waveform enables the study of the variability of pulse features, such as the amplitude and the pulse arrival time (PAT), and when quantified in the time and frequency domains, has considerable potential to shed light on perfusion changes associated with peripheral arterial disease (PAD). In this pilot study, innovative multi-site bilateral finger and toe PPG recordings from 43 healthy control subjects and 31 PAD subjects were compared (recordings each at least five minutes, collected in a warm temperature-controlled room). Beat-to-beat normalized amplitude variability and PAT variability were then quantified in the time-domain using two simple statistical measures and in the frequency-domain bilaterally using magnitude squared coherence (MSC). Significantly reduced normalized amplitude variability (healthy control 0.0384 (interquartile range 0.0217⁻0.0744) vs. PAD 0.0160 (0.0080⁻0.0338) (p < 0.0001)) and significantly increased PAT variability (healthy control 0.0063 (0.0052⁻0.0086) vs. PAD 0.0093 (0.0078⁻0.0144) (p < 0.0001)) was demonstrated for the toe site in PAD using the time-domain analysis. Frequency-domain analysis demonstrated significantly lower MSC values across a range of frequency bands for PAD patients. These changes suggest a loss of right-to-left body side coherence and cardiovascular control in PAD. This study has also demonstrated the feasibility of using these measurement and analysis methods in studies investigating multi-site PPG variability for a wide range of cardiac and vascular patient groups.
More Related Videos
08:38Intravital Microscopy of Monocyte Homing and Tumor-Related Angiogenesis in a Murine Model of Peripheral Arterial Disease
Published on: August 26, 2017
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Peripheral Artery Disease I: Introduction
Peripheral Artery Disease IV: Nursing Management
Peripheral Artery Disease III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Multi-input and Multi-variable systems
In the absence of...