Related Experiment Video
Updated: Feb 5, 2026

Quantification of Humic and Fulvic Acids in Humate Ores, DOC, Humified Materials and Humic Substance-Containing Commercial Products
Published on: March 18, 2022
[Control of Coagulant Dosing for Humic Substances Based on Ultraviolet Spectrum Analysis]
Bei-Chen Zhang1, Xiao-Lei Zhang1, Lan-Lan Qin1
1State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Beijing Normal University, Beijing 100875, China.
Abstract:
Humic substance (HS) is a main component of dissolved organic matter in the aquatic environment and significantly affects water treatment processes. To investigate the applicability and principle of UV spectrum analysis for coagulation control, laboratory jar tests were conducted with synthetic waters that had varying concentrations of HS and kaolinite. Thus, the influence of water quality conditions on the optimal coagulant dose (OCD) was determined and further correlated to Specific Ultraviolet Absorbance (SUVA254) and the ultraviolet spectral slopes of the coagulated water. Subsequently, the relationship between the UV spectral slopes and organic fractionation was further identified by using size exclusion chromatography (SEC). The results showed that the coagulant demands of the synthetic waters were positively related to dissolved organic carbon (DOC). Consequently, a stoichiometric relationship (0.61 mg·mg-1 calculated as Al/DOC) was found between the coagulant demand and initial DOC of the synthetic water. As the coagulant dose increased, SUVA254 decreased from 8.9 L·(mg·m)-1 to a steady level of 2.0 L·(mg·m)-1 and the removal efficiency of DOC was positively correlated with SUVA254. Spectral slopes in different wavelength ranges had showed similar tendencies, with S275-295 having the best correlation with SUVA254 (R2=0.81). Furthermore, SEC results demonstrated that coagulation preferentially removed humic substances, leading to reduced humification. As a result, S275-295 had the highest correlation with the portion of UVA254 contributed by humic substances in water. Therefore, online measurement of ultraviolet spectral slopes was an important aspect in the control of coagulant dosing.
Related Concept Videos
The Electromagnetic Spectrum
The Electromagnetic Spectrum
Coagulation
Coagulation
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant

