Related Experiment Video
Updated: Feb 5, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Treatment of Distal Radial Fractures by Open Reduction and Internal Fixation with a Volar Locking Plate
Nathan S Mauser1, Michel Y Benoit1, Nathan T Morrell1
1Department of Orthopedics and Rehabilitation, University of Vermont Medical Center, Burlington, Vermont.
Abstract:
The volar locking plate is a popular implant for surgical management of unstable distal radial fractures. We routinely utilize this system for all distal radial fractures except for those with entrapped intra-articular fragments and fractures with a displaced dorsomedial facet fracture (which is hard to capture with the volar approach alone). In this video, we describe in detail the necessary steps for successful placement of the volar locking plate, starting with preoperative planning and ending with expected outcomes. The approach that we utilize is through the flexor carpi radialis tendon sheath and avoids the radial artery. In the video, we describe 4 variations on the application of a volar locking plate: (1) the standard technique after appropriate reduction and provisional fixation with Kirschner wires, (2) regaining length through a shortened distal radial fracture, (3) using the volar plate to assist in the reduction and regain volar tilt, and (4) intraoperative management of coronal shift of the distal fragment. Complications reported for the volar locking plate have decreased with newer low-profile plate designs; however, they still include volar tendon irritation and/or rupture and median neuropathy. Postoperatively, we advise a brief 2-week period of immobilization for wound-healing, which is followed by a period during which a removable wrist splint is used and patients are instructed on the performance of a hand therapy regimen.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Internal Energy
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Internal Receptors
Oxidation-Reduction Reactions
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: