Related Experiment Video
Updated: Feb 5, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Cardiac Conduction Model for Generating 12 Lead ECG Signals With Realistic Heart Rate Dynamics
Abstract:
We present an extended heterogeneous oscillator model of cardiac conduction system for generation of realistic 12 lead ECG waveforms. The model consists of main natural pacemakers represented by modified van der Pol equations, and atrial and ventricular muscles, in which the depolarization and repolarization processes are described by modified FitzHugh-Nagumo equations. We incorporate an artificial RR-tachogram with the specific statistics of a heart rate, the frequency-domain characteristics of heart rate variability produced by Mayer and respiratory sinus arrhythmia waves, normally distributed additive noise and a baseline wander that couple the respiratory frequency. The standard 12 lead ECG is calculated by means of a weighted linear combination of atria and ventricle signals and thus can be fitted to clinical ECG of real subject. The model is capable to simulate accurately realistic ECG characteristics including local pathological phenomena accounting for biophysical properties of the human heart. All these features provide significant advantages over existing nonlinear cardiac models. The proposed model constitutes a useful tool for medical education and for assessment and testing of ECG signal processing software and hardware systems.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...

