Related Experiment Video
Updated: Feb 5, 2026

Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Candidate reference measurement procedure for determination of urea in serum by liquid chromatography-tandem mass
Liqiao Han1, Xiaoting Huang1, Lu Zhang1
1Department of Laboratory Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China.
Abstract:
Urea is an important indicator of liver and kidney disease, and very frequently determined in clinical chemistry. The reference measurement procedures (RMPs) for serum urea recognized by the Joint Committee for Traceability in Laboratory Medicine are spectrophotometry, and isotope dilution (ID)-mass spectrometry (MS) coupled with gas chromatography. This study investigated a candidate RMP (cRMP) for detecting serum urea directly via ID-liquid chromatography (LC)-MS/MS, without derivatization, which simplifies pre-processing samples. The cRMP was developed and evaluated relative to the recognized RMP, inter- and intra-laboratories. The intra-precisions were 1.35%, 1.98% and 1.47% at 4.95, 24.74 and 31.36 mmol/L, respectively; inter-precision was 2.10%, 2.60% and 2.10%. The relative bias for the measurement of standard human serum (SRM 909c) was -0.49%. The relative biases were 0.41% and 0.02% for IFCC-RELA (International Federation of Clinical Chemistry and Laboratory Medicine-External Quality Assessment Scheme [EQAS] for reference laboratories) 2015A and 2015B. The linearity response between 2.4 mmol/L and 53.7 mmol/L was R2 = 0.9989. No carryover, ion suppression, or interference was detected. Correlation was acceptable with the reference spectrophotometry (R2 = 0.9985, P < 0.0001). Between our laboratory and other reference laboratories, the absolute deviation range for IFCC-RELA 2016A and 2016B was from -0.63 to 1.52 mmol/L. This well-characterized cRMP for urea can provide a base of accuracy for the traceability of clinical systems.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Mass Spectrometry: Overview