Related Experiment Video
Updated: Feb 5, 2026

Primed Mycobacterial Uveitis PMU as a Model for Post-Infectious Uveitis
Published on: December 17, 2021
Analysis of ocular inflammation in anterior chamber-involving uveitis using swept-source anterior segment OCT
Elmira Baghdasaryan1, Tudor C Tepelus1, Kenneth M Marion1
1Doheny Eye Institute, 1355 San Pablo Street, DVRC 211, Los Angeles, CA, 90033, USA.
Purpose:
To evaluate the utility of swept-source (SS) optical coherence tomography (OCT) to objectively analyze the degree of anterior chamber (AC) inflammation.
Methods:
Thirty-eight eyes of 32 patients with uveitis and 20 control eyes were enrolled. SS OCT B-scans were obtained, and the number of cells in the B-scans was counted using two methods: (1) manual grading by Point Picker plug-in of Image J ( http://bigwww.epfl.ch/thevenaz/pointpicker/ ) and (2) automated grading by the Image J Particle Analysis algorithm ( http://imagej.net/Particle_Analysis ). The automated and manual AC cell counts were correlated with the Standardization of Uveitis Nomenclature score.
Results:
The average numbers of AC inflammatory cells counted by the automated method were 8 ± 4.0, 18 ± 3.0, 42 ± 14.0, 81 ± 32.0, 117 ± 57.0, and 275 ± 67.0 cells/mm2 for grades 0, 0.5 + , 1 + , 2 + , 3 + , and 4 + , respectively. For the same clinical categories, the average manual cell counts were 6 ± 4.0, 18 ± 3.0, 34 ± 14.0, 72 ± 32.0, 92 ± 43.0, and 168 ± 65.0 cells/mm2, respectively. Zero cells were detected in the AC of healthy eyes. The automated and manual methods were highly correlated (R = 0.98, p < 0.001) and showed good correlation with the clinical grading (R = 0.88, p < 0.001). A mean AC particle size of 117.4 ± 108.8 μm was obtained by the automated method.
Conclusions:
Quantification of the AC cells imaged by SS AS-OCT shows good correlation with categorical clinical severity assessments in uveitis eyes. This approach may provide a more objective method for monitoring uveitis and response to uveitis therapy.
Related Concept Videos
Muscles of the Anterior Neck
Inflammation
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Chambers of the Heart
Deoxygenated blood from the body is received in the right...
Antigens Involved in Adaptive Immunity
Complete Antigens
Complete antigens possess both immunogenicity and...

