Related Experiment Video
Updated: Feb 5, 2026

Step-by-Step Stapedotomy through Transcanal Exclusive Endoscopic Approach
Published on: March 5, 2022
Outcomes of Stapedotomy With Heat-Crimped Prostheses
John Murfee1, Brendan O'Connell2, David Haynes2
1Quillen College of Medicine, Johnson City.
Background:
Theoretical disadvantages are associated with the use of heat-crimped piston prostheses in stapedotomy. Loose crimping could result in prosthesis displacement or slippage. Alternatively, overly tight crimping may cause trauma to the incus with resultant necrosis.
Objectives:
1) Analyze outcomes of patients undergoing stapedotomy with heat-activated piston-style prostheses, and 2) compare outcomes between prostheses made by different manufacturers.
Study Design:
Retrospective.
Setting:
Vanderbilt Medical Center.
Patients And Methods:
Cases undergoing stapedotomy between 2005 and 2016 were reviewed. Audiometric assessments were recorded in accordance with American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) guidelines. Patients who lacked audiometric follow-up before 6 months or after 1 year were excluded.
Intervention(S):
Diagnostic, therapeutic, and rehabilitative.
Main Outcome Measure(S):
Postoperative air-bone gap (ABG) and achievement of an ABG is less than or equal to 10 dB.
Results:
Three hundred fifty-eight patients met inclusion criteria. At short-term follow-up (<6 mo), the mean ABG was 11 ± 8 dB in the entire cohort; this did not differ based on manufacturer (p = 0.13). The majority of patients (63%) achieved an ABG less than or equal to 10 dB. At longer-term follow-up, the mean ABG was 9 ± 7 dB; again no differences were noted when comparing prosthesis manufacturer (p = 0.20). 70% of patients achieved an ABG less than or equal to 10 dB at longer-term follow-up. When comparing short- to long-term follow-up, ABG did not significantly change over time (p = 0.76). The overall revision rate was 1.9% (n = 7).
Conclusion:
Favorable hearing outcomes are obtained both short- and long-term following stapedotomy and placement of heat-crimped piston prostheses. Both prosthesis groups appear stable in the middle ear environment long-term, as evidenced by a 1.9% revision rate among them.
Related Concept Videos
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Quantifying Heat
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Heat Flow and Specific Heat
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...