Patient-ventilator interaction with conventional and automated management of pressure support during difficult
Domenico Luca Grieco1, Maria Maddalena Bitondo1, Hernan Aguirre-Bermeo2
1Department of Anesthesiology and Intensive Care, Catholic University of the Sacred Heart, Fondazione Policlinico Universitario 'A. Gemelli' IRCCS, Largo Agostino Gemelli, 8, 00168 Rome, Italy.
Purpose:
Optimizing pressure support ventilation (PSV) can improve patient-ventilator interaction. We conducted a two-center, randomized cross-over study to determine whether automated PSV lowers asynchrony rate during difficult weaning from mechanical ventilation.
Methods:
Thirty patients failing the first weaning attempt were randomly ventilated for 2 three-hour consecutive periods with: 1)PSV managed by physicians (convPSV); 2)PSV managed by Smartcare® (autoPSV). These 2 periods were applied in the afternoon and overnight, for a 12-h total study time. Two independent clinicians offline analyzed ventilator waveforms to compute asynchrony index(AI).
Results:
AI was lower during autoPSV than during convPSV (medians[interquartile ranges] 5.1[2.6-9.5]% vs. 7.3[2.3-13.4]%, p = 0.02), without changes in the proportion of patients with AI>10%(p = 0.31). Pressure support (PS) variability was higher during autoPSV (p < 0.001), but average PS did not vary. In patients with baseline PS > 12 cmH2O (n = 15), PS and tidal volume were lower with autoPSV (12 [10-15]cmH2O vs. 15 [14-18]cmH2O,p = 0.003; 7.2[6.2-8.3]ml/Kg vs. 8.2[7.1-9.1]ml/Kg, p = 0.02) and AI reduction was driven by lower tidal volume (p = 0.03). In patients with baseline PS ≤ 12 cmH2O, AI reduction during autoPSV was mediated by increased PS variability (p = 0.04).
Conclusion:
During difficult weaning, autoPSV improves patient-ventilator interaction by lowering tidal volume and enhancing PS variability. In expert centres, however, the size effect of the intervention appears clinically small, likely because physicians themselves adequately limit PS and tidal volume.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: