Computed Tomography Urography: Comparison of Image Quality and Radiation Dose between Single- and Split-Bolus
John Nathan Gifford1, Mei Choo Chong, Le Roy Chong
1Department of Radiology, Changi General Hospital, Singapore.
Introduction:
In this study, we aimed to compare the split-bolus and single-bolus computerised tomography (CT) urography and determine if this offers a reduction in radiation dose without compromising image quality.
Materials And Methods:
A retrospective evaluation was performed on 88 patients undergoing split-bolus CT urography and this was compared to a control group of 101 consecutive patients undergoing single-bolus CT urography. A radiation dose analysis was performed on each subject. Subjects with urinary bladder lesions, hydronephrosis, renal masses or cysts >3 cm in diameter were excluded. All images were classified according to image quality by 2 consultant radiologists.
Results:
Opacification of the renal parenchyma, pelvicalyceal system, proximal ureters and urinary bladder were comparable between the 2 techniques, whilst image quality of the middle and distal third of the ureters was better using the split-bolus technique. The mean dose length product (DLP) for the single-bolus technique was 1324.1 mGy-cm, whilst that of the split-bolus technique was 885.7 mGy-cm. The mean effective dose reduction was calculated to be 31.1% between the 2 groups.
Conclusion:
The split-bolus technique gives a reduced radiation dose without compromising image quality. The associated reduction in images is beneficial for data storage and reporting efficiency. As such, our department will adopt the split-bolus technique for young, low-risk patients.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Biological Effects of Radiation
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Bioavailability Study Design: Single Versus Multiple Dose Studies
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...