Related Experiment Video
Updated: Feb 4, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
[Study of the Impact of Sample Thickness on Thin Film Method X-Ray Fluorescence Spectrum Measurement]
Abstract:
The mixed samples of nylon film enrichment of Cr, Pb and Cd three elements and glass fiber membrane filter were as the research object. With the method of superposition of membrane filter, the XRF spectra were measured under different thin film samples thicknesses. According the changes of characteristic XRF of Cr, Pb and Cd elements in the mixed sample and Ca, As and Sr elements in glass fiber membranes, the effects of sample thickness on thin film method XRF spectrum measurement were studied. The study results showed that the effects of thin film sample thickness on the fluorescent properties of elements with characteristic spectral lines in different energy ranges were different. The energy of characteristic spectral lines was greater, the loss of element characteristic X-ray fluorescence when it passed through membrane and reached detector was less. But matrix effect caused by thin film sample thickness increase was stronger with the energy of characteristic spectral lines greater. The background fluorescent intensity in corresponding characteristic spectral line location was greater. So the impact of matrix effect caused by sample thickness increase on thin film method XRF spectrum measurement sensitivity was greater. For elements with low energy characteristic spectral lines (energy≤7 keV), the way of increasing thin film sample thickness in order to increase the mass-thickness concentration of component measured, can not effectively improve the sensitivity of thin film method XRF spectrum measurement. And thin film samples thickness within 0.96 mm is conductive to the measurement and analysis of XRF spectrum. For element with higher energy characteristic spectra lines(energy>7 keV), the sensitivity of XRF spectrum measurement can be appropriately increased by the way of increase thin film sample thickness in order to increase the mass-thickness concentration of component measured. And thin film samples thickness within 0.96~2.24 mm is more conductive to the measurement and analysis of XRF spectrum. The study provides an important theoretical basis for thin sample preparation and enrichment technology of thin film method X-ray fluorescence spectrum analysis the atmosphere and water heavy metal.
Related Concept Videos
The Electromagnetic Spectrum
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...

