Related Experiment Video
Updated: Feb 4, 2026

Knowledge Based Cloud FE Simulation of Sheet Metal Forming Processes
Published on: December 13, 2016
A Reduced Form Model for Ozone Based on Two Decades of CMAQ Simulations for the Continental United States
P Steven Porter1, S T Rao2, Christian Hogrefe3
1Porter-Gego, Idaho Falls, ID.
Abstract:
A Reduced Form Model (RFM) is a mathematical relationship between the inputs and outputs of an air quality model, permitting estimation of additional modeling without costly new regional-scale simulations. A 21-year Community Multiscale Air Quality (CMAQ) simulation for the continental United States provided the basis for the RFM developed in this study. Predictors included the principal component scores (PCS) of emissions and meteorological variables, while the predictand was the monthly mean of daily maximum 8-hour CMAQ ozone for the ozone season at each model grid. The PCS form an orthogonal basis for RFM inputs. A few PCS incorporate most of the variability of emissions and meteorology, thereby reducing the dimensionality of the source-receptor problem. Stochastic kriging was used to estimate the model. The RFM was used to separate the effects of emissions and meteorology on ozone concentrations. by running the RFM with emissions constant (ozone dependent on meteorology), or constant meteorology (ozone dependent on emissions). Years with ozone-conducive meteorology were identified, and meteorological variables best explaining meteorology-dependent ozone were identified. Meteorology accounted for 19% to 55% of ozone variability in the eastern US, and 39% to 92% in the western US. Temporal trends estimated for original CMAQ ozone data and emission-dependent ozone were mostly negative, but the confidence intervals for emission-dependent ozone are much narrower. Emission-driven changes in monthly mean ozone levels for the period 2000-2010 ranged from 6.4 to 10.9 ppb for the eastern US and from 1.4 to 2.5 ppb for the western US.
More Related Videos
Related Concept Videos
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Measurement: Standard Units
Measurement: Derived Units
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...

