Related Experiment Video
Updated: Feb 4, 2026

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Detection of Chromium Content in Soybean Oil by Laser Induced Breakdown Spectroscopy and UVE Method
Abstract:
In order to monitor chromium (Cr) content in soybean oil, laser induced breakdown spectroscopy (LIBS) was used to detect Cr content in this research. Pine wood chips was used to enrich heavy metal of Cr, and the spectra of pine wood chips were acquired in the wavelength range of 206.28~481.77 nm by a two-channel high-precision spectrometer. Then, uninformative variable elimination (UVE) method was used to select sensitive wavelength variables for heavy metal of Cr, and calibration model of Cr in soybean oil was developed with partial least squares (PLS) regression, the performance of the calibration model was compared to univariate and full PLS calibration models. The results indicate that the performance of UVE-PLS calibration model is better than that of univariate and full PLS calibration models, the correlation coefficient, root mean square error of calibration (RMSEC), root mean square error of cross validation (RMSECV), root mean square error of prediction (RMSEP) are 0.990, 0.045 mg·g-1, 0.050 mg·g-1 and 0.054 mg·g-1, respectively. After UVE variable selection, the number of wavelength variables in UVE-PLS calibration model is about 2% of wavelength variables in full PLS calibration model. This means UVE is an effective variable selection method which can select correlative variables for heavy metal of Cr.
More Related Videos
10:17Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Stereotype Content Model
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Design Example: Flow of Oil Through Circular Pipes
Measurement of Air Content in Concrete
The pressure method,...