Modeling Ramp-hold Indentation Measurements based on Kelvin-Voigt Fractional Derivative Model
HongMei Zhang1, QingZhe Zhang2, LiTao Ruan3
1Key Laboratory of Biomedical Information Engineering, Ministry of Education, School of Life Science and Technology, Xi'an JiaoTong University, Xianning West Road No.28, Xi'an, Shaanxi, 710049, P. R. China.
Abstract:
Interpretation of experimental data from micro- and nano-scale indentation testing is highly dependent on the constitutive model selected to relate measurements to mechanical properties. The Kelvin-Voigt Fractional Derivative model (KVFD) offers a compact set of viscoelastic features appropriate for characterizing soft biological materials. This paper provides a set of KVFD solutions for converting indentation testing data acquired for different geometries and scales into viscoelastic properties of soft materials. These solutions, which are mostly in closed-form, apply to ramp-hold relaxation, load-unload and ramp-load creep-testing protocols. We report on applications of these model solutions to macro- and nano-indentation testing of hydrogels, gastric cancer cells and ex vivo breast tissue samples using an Atomic Force Microscope (AFM). We also applied KVFD models to clinical ultrasonic breast data using a compression plate as required for elasticity imaging. Together the results show that KVFD models fit a broad range of experimental data with a correlation coefficient typically R2 > 0.99. For hydrogel samples, estimation of KVFD model parameters from test data using spherical indentation versus plate compression as well as ramp relaxation versus load-unload compression all agree within one standard deviation. Results from measurements made using macro- and nano-scale indentation agree in trend. For gastric cell and ex vivo breast tissue measurements, KVFD moduli are, respectively, 1/3 - 1/2 and 1/6 of the elasticity modulus found from the Sneddon model. In vivo breast tissue measurements yield model parameters consistent with literature results. The consistency of results found for a broad range of experimental parameters suggest the KVFD model is a reliable tool for exploring intrinsic features of the cell/tissue microenvironments.
Related Concept Videos
Measurement: Derived Units
Gas Thermometers and the Kelvin Scale
The Quantum-Mechanical Model of an Atom
Molecular Models
Base Quantities and Derived Quantities
The International Organization for...
The Bohr Model