Related Experiment Video
Updated: Feb 4, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Nanogap-Based Electrochemical Measurements at Double-Carbon-Fiber Ultramicroelectrodes
Pavithra Pathirathna1, Ryan J Balla1, Shigeru Amemiya1
1Department of Chemistry , University of Pittsburgh , Pittsburgh , Pennsylvania 15260 , United States.
Abstract:
Electrochemical measurements with unprecedentedly high sensitivity, selectivity, and kinetic resolution have been enabled by a pair of electrodes separated by a nanometer-wide gap. The fabrication of nanogap electrodes, however, requires extensive nanolithography or nanoscale electrode positioning, thereby preventing the full exploration of this powerful method in electrode design and application. Herein, we report the simple fabrication of double-carbon-fiber ultramicroelectrodes (UMEs) with nanometer-wide gaps not only to facilitate nanogap-based electrochemical measurements but also to gain high time resolution, signal-to-background ratio, and kinetic selectivity for dopamine against ascorbic acid. Specifically, ∼7 μm-diameter carbon fibers are inserted into a double-bore glass capillary, heat-pulled, and milled by focused ion-beam technology to yield ∼50 μm-long double-cylinder UMEs. The redox cycling of the Ru(NH3)63+/2+ couple across a nanogap between voltammetric generator and amperometric collector electrodes reaches quasi-steady states at fast scan rates of 100 V/s as demonstrated experimentally and even 1000 V/s as predicted theoretically. The transient background of the amperometric collector response is suppressed ∼100 times in comparison with that of the voltammetric generator response. Nanogap voltammograms based on the collector response against the cycled generator potential are quantitatively analyzed without background subtraction to reproducibly yield nanogap widths of ∼0.18 μm and a standard electron-transfer rate constant of 0.9 cm/s. Moreover, nanogap-mediated redox cycling can be initiated by dopamine oxidation at the generator electrode to largely improve the dopamine selectivity of the collector response against ascorbic acid, which is also oxidized at the generator electrode to immediately and irreversibly produce a redox-inactive species.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Carbon Skeletons
The Carbon Cycle
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...
Fixing Double-strand Breaks

