[Common cold or whooping cough]

Ann-Christin Sundelin1, Erik Tingberg1

  • 1Inspektionen för vård och omsorg - Avdelning Syd Malmö, Sweden Inspektionen för vård och omsorg - Avdelning Syd Malmö, Sweden.

Lakartidningen
|September 26, 2018
PubMed

Insights

Early intervention is crucial for infants under 6 months with suspected whooping cough (pertussis). Prophylactic treatment should commence immediately, even before test results, to prevent severe illness and fatalities.

Area of Science:

  • Pediatrics
  • Infectious Diseases
  • Public Health

Background:

  • Whooping cough (pertussis) poses a significant threat to infants.
  • Limited awareness of pertussis prevalence and restrictive antibiotic practices may impact treatment.
  • Concurrent respiratory syncytial virus (RSV) season can complicate diagnosis and treatment.

Observation:

  • Two severe cases of pertussis in infants under 6 months were reported by IVO by 2017.
  • One infant, aged 4 weeks, tragically died from the infection.
  • Cases occurred during a period of high RSV activity.

Findings:

  • Delayed or inadequate treatment may be linked to insufficient knowledge of local pertussis circulation.
  • Restrictive antibiotic prescribing may hinder effective management.
  • Early diagnosis and prompt initiation of prophylaxis and treatment are vital for optimal outcomes.

Implications:

  • Infants under 6 months with suspected pertussis exposure require immediate prophylactic treatment, irrespective of test results.
  • Enhanced public health surveillance and education on pertussis are necessary.
  • Guidelines should emphasize early empirical treatment for high-risk infants.

Related Concept Videos

Common Ion Effect03:24

Common Ion Effect

Compared with pure water, the solubility of an ionic compound is less in aqueous solutions containing a common ion (one also produced by dissolution of the ionic compound). This is an example of a phenomenon known as the common ion effect, which is a consequence of the law of mass action that may be explained using Le Châtelier’s principle. Consider the dissolution of silver iodide:
46.8K
Responses to Heat and Cold Stress02:45

Responses to Heat and Cold Stress

Every organism has an optimum temperature range within which healthy growth and physiological functioning can occur. At the ends of this range, there will be a minimum and maximum temperature that interrupt biological processes.
14.8K
Cold Weather Concreting01:27

Cold Weather Concreting

When freshly poured concrete is exposed to freezing temperatures before it has set, the water within the concrete can freeze. This expansion disrupts the setting process, delays chemical reactions necessary for hardening, and increases the volume of pores within the hardened concrete, which weakens its overall structure. If the concrete manages to reach an appreciable strength before it freezes, the damage can be somewhat mitigated.
To counteract the negative impacts of cold weather, ensuring...
384
Common Respiratory Disorders01:31

Common Respiratory Disorders

Respiratory disorders, a prevalent health concern globally, are generally divided into two primary categories: upper and lower respiratory tract disorders. The categorization is based on the area of the respiratory system they affect.
Upper respiratory disorders impact the airways above the vocal cords, encompassing areas like the nose, sinuses, and throat. Various conditions fall under this category, including the common cold and allergic rhinitis. These disorders can stem from several causes,...
1.4K
Masonry in Cold and Hot Weather Conditions01:21

Masonry in Cold and Hot Weather Conditions

In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
348
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.6K