Related Experiment Video
Updated: Feb 4, 2026

Simultaneous Label-Free Autofluorescence Multi-Harmonic Microscopy
Published on: August 29, 2025
Calculations of second harmonic generation with radially polarized excitations by elliptical mirror focusing
1Institute of Ultra-precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin, China.
Abstract:
Second harmonic generation (SHG) polarization intensity distribution illuminated with radially polarized beams by lens focusing appears two peaks, when the nonlinear optical coefficients dominate that is relevant to the transverse electric field components. Such two peaks pattern may result in ghosting and the decrement of imaging resolution. In this paper, an elliptical mirror based system is proposed in the case of radially polarized beams illumination for SHG. The calculated predictions and numerical simulations demonstrate that for radially polarized beams, the proportion of transverse field components at the focal plane under the condition of elliptical mirror focusing is 2.6 times smaller than that with lens focusing when its numerical aperture (NA) is 1. Furthermore, the full width at half maximum (FWHM) of the total field intensity profile is approximately 81% of that in a lens focusing system. Due to the enhancement of longitudinal components of incident field, the distribution of SHG polarization presents a single-peak pattern, in which two peaks can be observed with lens focusing. The SHG polarizations in collagen fiber, KTiOPO4 , and LiNbO3 have been numerical simulated and discussed in detail to verify the validity of the proposed method. LAY DESCRIPTION: A novel focusing mode for second harmonic generation (SHG) microscopy is described in this paper. In the case of radially polarized excitations, the SHG polarization distributions of some specimens appear two peaks pattern with traditional lens focusing. Such two peaks pattern may result in ghosting and the decrement of imaging resolution. By introducing elliptical mirror, the modulation of electric field at the focal plane can be realized. Thus, the distribution of SHG polarization is converted into a single-peak pattern which eliminates the ghosting and improves the spatial resolution on SHG images. This proposed method can be used for SHG in various materials and the full width at half maximum (FWHM) of SHG polarization will compress in different degrees. Besides, there is a significant improvement on signal-to-noise ratio in SHG imaging when an annular aperture illumination is applied. The focusing mode with elliptical mirror can also be utilized in other nonlinear optics areas such as polarized third harmonic generation (THG) measurements and two-photon fluorescence (TPF) microscopy.
More Related Videos
07:56A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Group Polarization
Molecular Shape and Polarity
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Simple Harmonic Motion
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation: