Diagnostic accuracy of cone-beam breast computed tomography: a systematic review and diagnostic meta-analysis
Johannes Uhlig1,2, Annemarie Uhlig3, Lorenz Biggemann4
1Department of Diagnostic and Interventional Radiology, University Medical Center Goettingen, Robert-Koch-Str. 40, 37075, Goettingen, Germany. Johannes.uhlig@med.uni-goettingen.de.
Purpose:
To review the published evidence on cone-beam breast computed tomography (CBBCT) and summarize its diagnostic accuracy for breast lesion assessment.
Materials And Methods:
A systematic literature search was conducted using the EMBASE, MEDLINE and CENTRAL libraries. Studies were included if reporting sensitivity and specificity for discrimination of benign and malignant breast lesions via breast CT. Sensitivity and specificity were jointly modeled using a bivariate approach calculating summary areas under the receiver-operating characteristics curve (AUC). All analyses were separately performed for non-contrast and contrast-enhanced CBBCT (NC-CBBCT, CE-CBBCT).
Results:
A total of 362 studies were screened, of which 6 with 559 patients were included. All studies were conducted between 2015 and 2018 and evaluated female participants. Four of six studies included dense and very dense breasts with a high proportion of microcalcifications. For NC-CBBCT, pooled sensitivity was 0.789 (95% CI: 0.66-0.89) and pooled specificity was 0.697 (95% CI: 0.471-0.851), both showing considerable significant between-study heterogeneity (I2 = 89.4%, I2 = 94.7%, both p < 0.001). Partial AUC for NC-CBBCT was 0.817. For CE-CBBCT, pooled sensitivity was 0.899 (95% CI: 0.785-0.956) and pooled specificity was 0.788 (95% CI: 0.709-0.85), both exhibiting non-significant moderate between-study heterogeneity (I2 = 57.3%, p = 0.0527; I2 = 53.1%, p = 0.0738). Partial AUC for CE-CBBCT was 0.869.
Conclusion:
The evidence available for CBBCT tends to show superior diagnostic performance for CE-CBBCT over NC-CBBCT regarding sensitivity, specificity and partial AUC. Diagnostic accuracy of CE-CBBCT was numerically comparable to that of breast MRI with meta-analyses reporting sensitivity of 0.9 and specificity of 0.72.
Key Points:
• CE-CBBCT rather than NC-CBBCT should be used for assessment of breast lesions for its higher diagnostic accuracy. • CE-CBBCT diagnostic performance was comparable to published results on breast MRI, thus qualifying CE-CBBCT as a potential imaging alternative for patients with MRI contraindications.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Pericarditis II: Clinical Features and Diagnostic Tests
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests