Related Experiment Video
Updated: Feb 4, 2026

Isolation of Double Negative αβ T Cells from the Kidney
Published on: May 16, 2014
Baseline Detrending for the Photopic Negative Response
Jessica Tang1,2, Flora Hui1,2, Michael Coote1,2
1Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.
Purpose:
The photopic negative response (PhNR) of the light-adapted electroretinogram (ERG) holds promise as an objective marker of retinal ganglion cell function. We compared baseline detrending methods to improve PhNR repeatability without compromising its diagnostic ability in glaucoma.
Methods:
Photopic ERGs were recorded in 20 glaucoma and 18 age-matched control participants. A total of 50 brief, red-flashes (1.6 cd.s/m2) on a blue background (10 photopic cd/m2) were delivered using the RETeval device. Detrending methods compared were: (1) increasing the high-pass filter from 1 to 10 Hz and (2) estimating and removing the trend with an increasing polynomial (order from 1-10) applied to the prestimulus interval, prestimulus and postsignal interval, or the whole ERG signal. Coefficient of repeatability (COR%), unpaired Student's t-test, and area under the receiver operating characteristic curve (AUC) were used to compare the detrending methods.
Results:
Most detrending methods improved PhNR test-retest repeatability compared to the International Society for Clinical Electrophysiology of Vision (ISCEV) recommended 0.3 to 300 Hz band-pass filter (COR% ± 200%). In particular, detrending with a polynomial (order 3) applied to the whole signal performed the best (COR% ± 44%) while achieving similar diagnostic ability as ISCEV band-pass (AUC 0.74 vs. 0.75, respectively). However, over-correcting with higher orders of processing can cause waveform distortion and reduce diagnostic ability.
Conclusions:
Baseline detrending can improve the PhNR repeatability without compromising its clinical use in glaucoma. Further studies exploring more complex processing methods are encouraged.
Translational Relevance:
Baseline detrending can significantly improve the quality of the PhNR.
Related Concept Videos
Negative Regulator Molecules
Positive, Negative, and Zero Work
Negative and Cognitive Symptoms of Schizophrenia
Negative Symptoms
Negative symptoms of schizophrenia manifest as deficits in normal emotional and behavioral functioning, profoundly impacting daily life. Individuals with schizophrenia often display a flat affect, characterized by a near-total absence of emotional expression,...
Responses to Gravity and Touch
Positive and Negative Feedback Loops
Gram-negative Bacterial Protein Secretion Systems

