Related Experiment Video
Updated: Feb 4, 2026

Fabrication of 3D Carbon Microelectromechanical Systems C-MEMS
Published on: June 17, 2017
Hyphenation of a MEMS based pre-concentrator and GC-IMS
Sascha Liedtke1, Stefano Zampolli2, Ivan Elmi2
1ION-GAS GmbH, Konrad-Adenauer-Allee 11, 44263 Dortmund, Germany.
Abstract:
A micro-electro-mechanical system (MEMS) based pre-concentrator filled with a standard Tenax TA adsorbent as well as with a synthetic receptor designed to adsorb 3-hydroxy-3-methylhexanoic acid (3H3MHA), a particular metabolite only available from human beings, was adapted to a custom made ion mobility spectrometer with gas-chromatographic pre-separation (GC-IMS). This combination was compared to a traditional sample loop GC-IMS. The application of a pre-concentrator is highly beneficial for the GC-IMS as analysing technique. By variation of the adsorbed sample volume, the system can be adapted to changing sample concentration ranges easily, thus increasing sensitivity significantly. Detection limits of few hundred ppqV could be obtained in this work for eucalyptol and 3 human metabolites (benzaldehyde, 2-ethyl-1-hexanol and decanal) as exemplary analytes. Moreover, the appropriate choice of selective pre-concentration phases in the pre-concentrator enables an adaptation of sampling to the composition of the mixture. Relevant compounds in very low concentrations can be amplified by using specially designed cavitands while interfering substances could be suppressed. This was successfully demonstrated by detecting 3H3MHA, a compound exclusively available in human sweat, which can be used to locate trapped or hidden individuals.
Related Concept Videos
pre-mRNA Processing
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a “cap” to the 5’ end of the growing transcript. In this process, a 5’ phosphate is replaced by modified guanosine that has a methyl group attached to it (7-Methyl...
Concentration Cells
Consider the following voltaic cell:
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Pre-mRNA Processing: Modification of pre-mRNA Ends
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a cap to the 5' end of the growing transcript. In this process, a 5' phosphate is replaced by modified guanosine that has a methyl group attached (7-methyl guanosine). This 5' cap helps...
Concentration and Rate Law
For example, in a generic reaction aA + bB ⟶ products, where a and b are stoichiometric coefficients, the rate law can be written as:
Solution Concentration and Dilution

