Related Experiment Video
Updated: Feb 4, 2026

Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation
Published on: October 10, 2018
A folding affinity paper-based electrochemical impedance device for cardiovascular risk assessment
Yuwadee Boonyasit1, Orawon Chailapakul2, Wanida Laiwattanapaisal3
1Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok 10330, Thailand.
Abstract:
A novel affinity paper-based electrochemical impedance device (PEID) was first fully developed for cardiovascular risk assessment. Herein, a simple folding PEID comprising a dual screen-printed electrode was fabricated for label-free electrochemical impedance detection. The results demonstrated in a step-wise manner that the phosphocholine-modified screen-printed carbon electrodes were highly responsive to the clinically required range of C-reactive protein (CRP) (0.005 - 500 mg L-1; r2 = 0.993) levels with a detection limit (3σ/slope) of 0.001 mg L-1. The optimal binding frequency of CRP-phosphocholine interaction was determined to be 100 Hz. These results implied that our proposed system could be used for simultaneously measuring the CRP levels using a single PEID platform in combination with the specific recognition elements. When assaying two levels of CRP, the overall assay reproducibility for each concentration, expressed as relative standard error of the mean (RSE%; n = 30), was 1.21%. The variation in the measurements between individual electrodes, expressed as the relative standard deviation (RSD), was 2.82%. Using 2 measurement sites per device, the proposed sensor provided excellent precision for the simultaneous detection of CRP. Moreover, the RSD for the CRP levels measured on ten independently fabricated paper-based sheets was 2.11%, thereby offering an acceptable fabrication reproducibility. The presented folding PEIDs were used forthe determination of CRP in patient-derived blood samples with minimised bias and excellent correlation with a standard method (n = 15; CUSUM linearity test, p > 0.10), thus permitting the potential application of PEID for assessing cardiovascular risk in individuals.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Protein Folding

