Related Experiment Video
Updated: Feb 4, 2026

Scalable Syntheses of Graphene Oxide and Reduced Graphene Oxide using Cascade Design Oxidation and Highly Basic Reduction Reactions
Published on: July 3, 2025
Reduced graphene-oxide transducers for biosensing applications beyond the Debye-screening limit
Xiaoling Lu1, Anna Miodek2, Walid-Madhat Munief3
1Institute of Materials in Electrical Engineering 1, RWTH Aachen University, Aachen, Germany; Department of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Zweibrücken, Germany.
Abstract:
In the field of label-free biosensing, various transducer materials and strategies are under investigation to overcome the Debye-screening limitation of charged biomolecules. We demonstrate an in-line, impedimetric aptasensor with reduced graphene-oxide (rGO) thin films as transducers to detect prostate specific antigens (PSA) in a physiological buffer solution. Unlike classical electrochemical impedance spectroscopy (EIS), this direct, label-free and fully-electronic biosensor approach does not need any redox markers. As specific capture molecules, short anti-PSA aptamers ensured a close binding of the target molecules to the transducer surfaces. Results showed a limit of detection smaller than 33 pM of PSA and a wide detection range from 0.033 to 330 nM fully covering the clinically relevant range of PSA (0.115-0.290 nM). This promising performance can be attributed to the bipolar electronic transport characteristics of the ultra-thin rGO layers similar to pristine graphene. The attachment of target biomolecules to the films changes the resistance of the rGO thin films. Such an in-line EIS configuration with rGO thin films opens promising prospects for biosensing beyond the Debye-screening limitation, which is a major challenge for conventional semiconductor field-effect devices towards clinical applications.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Redox Titration: Other Oxidizing and Reducing Agents
Oxidation Numbers
Limiting Reactant
Oxidation-Reduction Reactions
The Number e as a Limit
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...