Related Experiment Video
Updated: Feb 4, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Aortic and innominate routes for transcatheter aortic valve implantation
Jean Porterie1, Nicolas Mayeur2, Thibaut Lhermusier3
1Department of Cardiovascular Surgery, Rangueil University Hospital, Toulouse, France.
Objectives:
This study aimed at evaluating the efficacy and safety of the transaortic approach for the transcatheter aortic valve implantation procedure using balloon-expandable and self-expanding devices.
Methods:
From January 2012 to December 2016, the transaortic-transcatheter aortic valve implantation procedure was performed in 206 consecutive patients at the Rangueil University Hospital. All procedures were performed by a multidisciplinary heart team. The ascending aorta (27%) or innominate artery (73%) was exposed through a J-type manubriotomy. Events were adjudicated according to Valve Academic Research Consortium-2 criteria.
Results:
Mean age and logistic European System for Cardiac Risk Evaluation II were 83.9 ± 6.7 years and 16.8% ± 10.8%, respectively. Balloon-expandable and self-expanding valves were implanted in 59.7% and 40.3% of patients, respectively. Device success rate was 98.1%. Thirty-day overall mortality, cardiovascular mortality, cerebrovascular event, myocardial infarction, and permanent pacemaker implantation rates were 5.3%, 4.4%, 1.5%, 1.0%, and 9.7%, respectively (1-year rates: 15.5%, 9.2%, 3.9%, 3.4%, and 10.2%, respectively). Life-threatening bleeding and major vascular complications (7.3% and 3.9%, respectively) were not related to the central access site in approximately half of the cases. Multivariable Cox regression analysis identified preoperative renal failure as an independent predictor of overall mortality (odds ratio, 2.82; 95% confidence interval, 1.73-4.59; P < .0001). At the 1-year follow-up, most patients had experienced improved functional status and 98.4% of them were free of moderate to severe paravalvular leak.
Conclusions:
In a higher-risk subgroup within the patient population receiving transcatheter aortic valve implantation, transaortic-transcatheter aortic valve implantation was successfully performed in 98.1% of cases, with high functional improvement and low rates of mortality and adverse events, especially neurologic complications.
More Related Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Routes of Persuasion
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...