Evaluation of human observer performance on lesion detectability in single-slice and multislice dedicated breast cone
Minah Han1, Hanjoo Jang1, Jongduk Baek1
1School of Integrated Technology and Yonsei Institute of Convergence Technology, Yonsei University, 162-1, Incheon, Korea.
Purpose:
We evaluate the lesion detectability using human and model observer studies in single-slice and multislice cone beam computed tomography (CBCT) images with a breast anatomical background. The purposes of this work are (a) to compare human observer detectability between single-slice and multislice images for different signal sizes and noise structures, (b) to investigate the effect of different multislice viewing modes (i.e., sequential and simultaneous) on the detectability by a human observer, and (c) to predict the detectability by a human observer in single-slice and multislice images using single-slice channelized Hotelling observer (ssCHO) and multislice CHO (msCHO), respectively.
Methods:
Breast anatomical background is modeled using a power law spectrum of mammograms and the lesion is modeled with a spherical signal. We conduct signal-known-exactly and background-known-statistically detection tasks on transverse and longitudinal images reconstructed using the Feldkamp-Davis-Kress algorithm with Hanning and Ram-Lak weighted ramp filters. The human observer study is conducted on three different viewing modes: single-slice, and sequential and simultaneous multislice. To predict the detectability by a human observer, we use ssCHO and msCHO with anthropomorphic channels (i.e., dense difference-of-Gaussian (D-DOG) and Gabor channels) and internal noise.
Results:
The detectability by a human observer increases for multislice images compared to single-slice images. For multislice images, the sequential viewing mode yields higher detectability than the simultaneous viewing mode. However, the relative rank of detectability by a human observer for different signal sizes, image planes, and reconstruction filters is not much different between the viewing modes. Detectability by CHO with internal noise shows good correlation with that of the human observer for all viewing modes.
Conclusions:
Detectability by a human observer in CBCT images with breast anatomical background is affected by the image viewing mode, and the effect of the viewing mode depends on the signal size and noise structure. D-DOG and Gabor CHO with internal noise predict the detectability by a human observer well for both the single-slice and multislice image viewing modes.
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Background and Environment Affect Phenotype
An example of how genetic background affects phenotype can be seen in horses. The Extension gene in horses is responsible for their coat color. A wild-type gene (EE) produces black pigment in the coat, while a mutant gene (ee) produces red pigment. A...