Cytocompatibility and mechanical properties of surgical sealants for cardiovascular applications
Mark H Murdock1, Jordan T Chang1, Samuel K Luketich2
1Department of Surgery, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pa.
Objectives:
The present study compared physical, mechanical, and biologic characteristics of 4 clinically available surgical sealants for cardiovascular repair.
Methods:
BioGlue (Cryolife Inc, Kennesaw, Ga), PreveLeak (Mallinckrodt Pharmaceuticals, St Louis, Mo), Tridyne VS (BD, Franklin Lakes, NJ), and Coseal (Baxter Healthcare Corporation, Westlake Village, Calif) were compared for the following properties: hydrated swelling, cytocompatibility, burst strength, biaxial stretching (elasticity), and in vitro degradation.
Results:
Sealants showed a wide range of swelling upon hydration. By gravimetric and volumetric measurement, swelling was greatest for Coseal followed by Tridyne VS, BioGlue, and PreveLeak. Tridyne VS was the most cytocompatible based on Alamar Blue assay results, supporting 85% cell survival compared with 36% to 39% survival with the other sealants. All sealants withstood pressure above mean arterial pressure (70-110 mm Hg) and physiologic systolic blood pressure (90-140 mm Hg) in an ex vivo arterial flow burst model; lowest peak pressure at failure was PreveLeak at 235 ± 48 mm Hg, and highest peak pressure at failure was BioGlue at 596 ± 72 mm Hg. Biaxial tensile testing showed no differences in elasticity between ex vivo porcine aorta and carotid arteries and Tridyne VS or Coseal, and BioGlue and PreveLeak were significantly stiffer. In vitro degradation time for Coseal was 6 days and 21 days for Tridyne VS. No degradation was observed in BioGlue or PreveLeak for 30 days.
Conclusions:
Although all sealants withstood supraphysiologic arterial pressure, there were differences in characteristics that may be important in clinical outcome. Coseal degradation time was short compared with other sealants, whereas BioGlue and PreveLeak showed a significant compliance mismatch with native porcine carotid artery. Tridyne VS was significantly more cytocompatible than the other 3 sealants.
Related Concept Videos
Overview of the Cardiovascular System
Heart
The heart is the central pump of the cardiovascular system that circulates blood throughout the body. It comprises two atria receiving the blood and two ventricles pumping blood out of the heart. Their rhythmic contractions, called heartbeats, ensure that blood flow remains continuous.
Blood Vessels
Blood...
Regulation of the Cardiovascular System
The regulation of the cardiovascular system involves the autonomic nervous system (ANS), baroreceptors, and chemoreceptors, ensuring that heart rate and blood pressure are appropriately modulated in response to varying physiological demands.
The ANS comprises two main divisions: the sympathetic and parasympathetic nervous systems. The sympathetic nervous system enhances...
Physical and Chemical Properties of Matter
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Psychoneuroimmunology: Cardiovascular Disease
A key area of focus in PNI is the relationship between stress and coronary...