Effect of flow-encoding strength on intravoxel incoherent motion in the liver
Kévin Moulin1, Eric Aliotta1,2, Daniel B Ennis1,2,3
1Department of Radiological Sciences, University of California, Los Angeles, California.
Purpose:
To study the impact of variable flow-encoding strength on intravoxel incoherent motion (IVIM) liver imaging of diffusion and perfusion.
Theory:
Signal attenuation in DWI arises from (1) intravoxel microvascular blood flow, which depends on the flow-encoding strength α (first gradient moment) of the diffusion-encoding waveform, and (2) intravoxel spin diffusion, which depends on the b-value of the diffusion-encoding gradient waveforms α and b-value. Both are linked to the diffusion-encoding gradient waveform and conventionally are not independently controlled.
Methods:
In this work a convex optimization framework was used to generate gradient waveforms with independent α and b-value. Thirty-six unique α and b-value sample points from 5 different gradient waveforms were used to reconstruct perfusion fraction (f), coefficient of diffusion (D), and blood velocity standard deviation (Vb ) maps using a recently proposed IVIM model. Faster acquisition strategies were evaluated with 1000 random subsampling strategies of 16, 8, and 4 α and b-value. Among the subsampled reconstructions, the sampling schemes that minimized the difference with the fully sampled reconstruction were reported.
Results:
Healthy volunteers (N = 9) were imaged on a 3T scanner. Liver perfusion and diffusion estimates using the fully sampled IVIM method were f = 0.19 ± 0.06, D = 1.15 ± 0.15 10-3 mm2 /s, and Vb = 5.22 ± 3.86 mm/s. No statistical differences were found between the fully sampled and 2-times undersampled reconstruction (f = 0.2 ± 0.07, D = 1.19 ± 0.15 10-3 mm2 /s, Vb = 5.79 ± 3.43 mm/s); 4-times undersampled (f = 0.2 ± 0.06, D = 1.15 ± 0.17 10-3 mm2 /s, Vb = 4.66 ± 3.61 mm/s), or 8-times undersampled ( f = 0.2 ± 0.06, D = 1.23 ± 0.22 10-3 mm2 /s, Vb = 4.99 ± 3.82 mm/s) approaches.
Conclusion:
We demonstrate the IVIM signal's dependence on the b-value, the diffusion-encoding time and the flow-encoding strength and observe in vivo the ballistic regime signature of microperfusion in the liver. This work also demonstrates that using an IVIM model and sampling scheme matched to the ballistic regime, pixel-wise IVIM parameter maps are possible when sampling as few as 4 IVIM signals.
Related Concept Videos
Encoding
Automatic processing involves the encoding of details like time, space, frequency, and the meaning of words, usually done without conscious...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...