Related Experiment Video
Updated: Feb 4, 2026

A Mobile Outside-in Technique of Transforaminal Lumbar Endoscopy for Lumbar Disc Herniations
Published on: August 7, 2018
Elastomeric Lumbar Total Disc Replacement: Clinical and Radiological Results With Minimum 84 Months Follow-Up
Luiz Pimenta1,2, Luis Marchi1, Leonardo Oliveira1
1Instituto de Patologia da Coluna, São Paulo, Brazil.
Background:
Total lumbar disc replacement (TDR) devices have been designed to maintain motion, but both biomechanical and clinical data have indicated that a more controlled motion and additional load absorption in TDR would be beneficial. This work analyzed long-term results of an elastomeric disc (Physio-L) for degenerative lumbar conditions.
Material And Methods:
This was a prospective, noncomparative, single-center clinical and radiological study. A total of 15 patients with predominant low back pain due degenerative disc disease received anterior total disc replacement with a Physio-L disc. Clinical outcomes were assessed both with a visual analog scale for pain and Oswestry Disability Index questionnaires. Radiological outcomes included implant failure, range of motion (ROM), facet degeneration, and adjacent level disease. Complication and reoperation rates were also recorded. The cases were assessed with a minimum follow-up of 84 months.
Results:
A total of 15 patients were enrolled (20 TDRs)-10 single-level cases (L5S1) and 5 two-level cases (L4L5/L5S1). After 84 months, clinical outcomes scores still demonstrated significant improvement compared with baseline (P < .001). Mean visual analog scale scores dropped from 7.1 to 2.9, and the Oswestry Disability Index improved from 50 to 16. No disc has experienced migration or breakage. The average range of motion value went from a baseline of 12.0° to 13.3° at 12 months, and at the final follow-up it decreased to 9.9°. Regarding the double-level cases, 3 of 5 (60%) had adverse events; just 1 single-level (10%) had adverse events. At final follow-up, radiological signs of facet degeneration were present in 7 of 15 patients (47%) but with only 1 of 15 (6.7%) symptomatic. Two patients (13%) required surgery at the adjacent level. At the 84-month follow-up, 16 of 18 prostheses (89%) were still active (2 revised to fusion and 2 were lost to follow-up).
Conclusion:
The long-term follow-up data shows satisfactory clinical results for the use of Physio-L elastomeric TDR in the treatment of degenerative disc disease. Studies with bigger cohorts are needed to replicate results and add new information regarding other details.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Continuous Renal Replacement Therapy
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Total Voids in Concrete
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:

