Computed tomography evaluation of total knee arthroplasty implants position after two different surgical methods of
Francesco Benazzo1, Stefano Marco Paolo Rossi1, Gianmarco Danesino2
1Department of Clinical-Surgical Sciences, Diagnostics and Pediatrics, University of Pavia, Operative Unit of Orthopaedics and Traumatology, Fondazione IRCCS Policlinico San Matteo, Via Golgi, 19, 27100, Pavia, Italy.
Purpose:
The objectives of this study were to determine the reliability of a novel method of measuring the rotational alignment of an anatomical tibial tray, the difference in the rotational alignment of the femoral and tibial component according to pure measured resection or blended technique with tensor, and, finally, the difference in terms of clinical results according to the two different methods.
Patients And Methods:
We performed a total of 60 consecutive TKAs: 30 according to pure measured resection and 30 according to blended technique with tensor (FuZion®). Clinical scores and CT scan were done at six months to measure patient's outcome and prosthetic components rotation.
Results:
The method of measurement of tibial tray had high agreement between different radiological observers. Mean external rotation alignment of the femur was 2.7° in standard group and 0.5° in the FuZion® group. For all clinical indices, we observed a large and significant improvement at follow-up, better in blended technique group, but without a clear superiority, and no statistically significant difference was evident between the two groups. At follow-up, HSS was to 89.7 in the FuZion® group and 89.0 in the standard group, KSS (clinical) was 92.6 in and 91.3 respectively, and KSS (Functional) was 91.0 in the FuZion® group and 87.6 in the standard group.
Conclusions:
Our CT measurement method is reliable and reproducible. All patients operated with this personalized knee system design obtained excellent results; the customization of femoral rotation with a blended technique is, probably, the key to optimize the outcomes and achieve the state of forgotten knee.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...
Area Computation by the Alternative Coordinate Method
Velocity and Position by Graphical Method
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...