Requirements and Pitfalls of Dialyzer Sieving Coefficients Comparisons
Michael Hulko1, Ulrike Haug1, Julia Gauss1
1Research & Development, Baxter International Inc.
Abstract:
Sieving coefficients reported in dialyzer data sheets and instructions for use (IFUs) indicate the potential of different solutes to pass across a particular membrane. Despite being measured in vitro, sieving coefficient data are often used as a predictor of the clinical performance of dialyzers. Although standards for the measurement of sieving coefficients exist, the stated methodologies do not offer sufficient guidance to ensure comparability of test results between different dialyzers. The aim of this work was to investigate the relationship between sieving coefficients and published clinical performance indicators for two solutes, albumin loss and beta-2 microglobulin (β2 M) reduction ratio (RR), and to assess the impact of different in vitro test parameters on sieving coefficient values for albumin, β2 M, and myoglobin. Clinical albumin loss and β2 M RR for commercially available dialyzers used in hemodialysis (HD) and post-dilution hemodiafiltration (HDF) were extracted from the literature and plotted against sieving coefficients reported in data sheets and IFUs. Albumin, β2 M, and myoglobin sieving coefficients of a selection of dialyzers were measured per the ISO 8637 standard. The impact of in vitro testing conditions was assessed by changing blood flow rate, ultrafiltration (UF) rate, sampling time, and origin of test plasma. Results showed variation in albumin loss and β2 M RR for the same sieving coefficient across different dialyzers in HD and HDF. Changes in blood flow rates, UF rates, sampling time, and test plasma (bovine vs. human) caused marked differences in sieving coefficient values for all investigated solutes. When identical testing conditions were used, sieving coefficient values for the same dialyzer were reproducible. Testing conditions have a marked impact on the measurement of sieving coefficients, and values should not be compared unless identical conditions are used. Further, variability in observed clinical data in part reflects the lack of definition of test conditions.
Related Concept Videos
Drug Dissolution: Requirements and Profile Comparison
Coefficient of Variation
The coefficient of variation is a practical statistical tool in finance. It allows investors to assess the volatility or...
Sieve Analysis and Grading Curves
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the...
Confidence Coefficient
Thermodynamics: Activity Coefficient
The activity coefficient is a measure of the deviation from ideal behavior. When the ionic strength of the solution is minimal, the activity coefficient of an ionic species is close to unity, making...