Related Experiment Video
Updated: Feb 4, 2026

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Stride-to-stride fluctuations in transtibial amputees are not affected by changes in push-off mechanics from using
Chase G Rock1, Shane R Wurdeman2, Nicholas Stergiou1,3
1Department of Biomechanics, University of Nebraska at Omaha, Omaha, NE, United States of America.
Abstract:
Stride-to-stride fluctuations of joint kinematics during walking reflect a highly structured organization that is characteristic of healthy gait. The organization of stride-to-stride fluctuations is disturbed in lower-limb prosthesis users, yet the factors contributing to this difference are unclear. One potential contributor to the changes in stride-to-stride fluctuations is the altered push-off mechanics experienced by passive prosthesis users. The purpose of our study was to determine if changes in push-off mechanics affect stride-to-stride fluctuations in transtibial amputees. Twenty-two unilateral transtibial amputees were enrolled in the 6-week cross-over study, where High and Low Activity (based on the Medicare Functional Classification System) prostheses were worn for three weeks each. Data collection took place at the end of the third week. Participants walked on a treadmill in a motion capture laboratory to quantify stride-to-stride fluctuations of the lower extremity joint angle trajectories using the largest Lyapunov Exponent, and over floor-embedded force platforms to enable calculating push-off work from the prosthesis and the sound limb. Push-off work was 140% greater in the High Activity prosthesis compared to the Low Activity prosthesis (p < 0.001), however no significant change was observed in stride-to-stride fluctuations of the ankle between the two prosthesis types (p = 0.576). There was no significant correlation between changes in prosthesis push-off work and the largest Lyapunov exponent. Though differences in push-off work were observed between the two prosthesis types, stride-to-stride fluctuations remained similar, indicating that prosthesis propulsion mechanics may not be a strong determinant of stride-to-stride fluctuations in unpowered transtibial prosthesis users.
Related Concept Videos
Drive-Reduction Theory: Push Theory of Motivation
Reaction Mechanisms
For instance, the decomposition of ozone appears to follow a mechanism with two steps:
Mechanical Protein Functions
Mechanism of Conjugation
Mechanism of Angiogenesis
An Introduction to Mechanics
According to records, the history of mechanics starts with Aristotle (384–322 BC). He related mechanics to physical theory, aiming for a universal synthesis.
Newton defined mechanics as the branch of physical science that...

