Intra-arc binary collimation algorithm for the optimization of stereotactic radiotherapy treatment of multiple
R Lee MacDonald1, Christopher G Thomas1,2,3,4, Lucy Ward2
1Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
Purpose:
To design and implement a novel treatment planning algorithm based on a modification of dynamic conformal arc (DCA) therapy for the treatment of multiple cranial metastases with variable prescription doses.
Methods:
A workflow was developed in which separate dose matrices were calculated for each target at each control point (i.e., the multileaf collimator (MLC) was fit conformally to that single target). A cost function was used to quantify the relative contributions of each dose matrix in the plan to the overall plan objectives. Simulated annealing was used to allow for the inclusion or exclusion of individual dose matrices at each control point. The exclusion of individual targets at a given control point is termed intra-arc binary collimation (iABC) in this work and is accomplished by closing the MLCs over the target for a duration specified by simulated annealing optimization. Dynamic collimator motions were employed to minimize the variation between the idealized dose matrices (i.e., perfectly collimated targets) and actual dose matrices (i.e., MLC apertures that include quantities of nontarget tissue due to the relative orientations of targets in the field). An additional simulated annealing optimization was performed to weight the relative contributions of dose at each control point [referred to as the monitor unit distribution (MUD)] to improve compliance with plan objectives. The algorithm was tested on seven previously treated multiple metastases patients and plans were compared to the clinically treated VMAT plans.
Results:
Treatment plans generated with iABC used an average of 2716 (34%) fewer MU in the total plan than VMAT (P = 0.01). All normal tissue metrics for all plans and all patients were clinically acceptable. There were no statistically significant differences in any normal tissue dose metrics. Normalized prescription target coverage accuracy for all targets was 3% better on average for VMAT plans when compared to iABC (P = 0.07), and 14% better on average for iABC when compared to optimized DCA (P = 0.03).
Conclusion:
A novel method of aperture and dose distribution design has been developed to significantly increase the MU efficiency of single isocenter treatment of multiple metastases with variable prescription doses when compared to VMAT, and which improves target coverage accuracy significantly when compared to optimized DCA. By applying a DCA approach to subsets of targets across control points, a hybrid method of treatment delivery has been developed that combines the efficiency of dynamic conformal treatments and the dosimetric flexibility of VMAT.
Related Concept Videos
Multiple Allele Traits
Multiple Regression
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Multiple Bar Graph
Each bar or column in the multiple bar graph represents a data value. These graphs are used primarily in interrelating two or more sets of data. The categories of different kinds of data are listed along the horizontal or x-axis, whereas...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...