Remplissage Using Interconnected Knotless Anchors: Superior Biomechanical Properties to a Knotted Technique?
Tadanao Funakoshi1, Robert Hartzler2, Eduardo Stewien3
1University of Department of Orthopaedic Surgery, Hokkaido University School of Medicine, Sapporo, Japan.
Purpose:
To evaluate the biomechanical fixation strength and gap formation of 2 different remplissage fixation methods (double pulley knotted construct and interconnected knotless repair construct) in cadaver specimens.
Methods:
Seven matched pairs of human cadaveric shoulders were used for testing (mean age, 56 ± 10 years). A shoulder from each matched pair was randomly selected to receive a Hill-Sachs remplissage using either a knotted (No. 2 FiberWire double pulley with 3.0-mm SutureTak anchors) or knotless (coreless No. 2 FiberWire interconnected between 3.9-mm knotless CorkScrew anchors) double mattress construct. The tendon was cycled between 10 and 100 N at 1 Hz for 100 cycles, followed by a single-cycle pull to failure at 33 mm/s. Cyclic displacement, load to clinical failure (5 mm), yield load, and mode of failure were recorded.
Results:
Neither construct demonstrated clinical failure under cyclic loading. Load to clinical failure was higher for the knotless repair than that of the knotted repair (788 ± 162 N vs 488 ± 227 N; P = .003). The yield load was higher for the knotless repair than that of the knotted repair (1,080 ± 298 N vs 591 ± 265 N; P = .008). The most common failure mode for the knotted repair was knot failure or tendon tearing, whereas the failure mode for the knotless repair was by anchor pull-out or tendon tear with no failures occurring via the interconnected suture construct mechanism.
Conclusions:
In this biomechanical study comparing cyclic and ultimate loading for 2 double mattress remplissage repairs, the construct using interconnected, knotless sutures outperformed the knotted construct. No failure of the interconnected suture construct mechanism by slippage or breakage was observed in the knotless group.
Clinical Relevance:
The use of the interconnected knotless suture technique might improve the biomechanical strength of arthroscopic remplissage repairs in treating shoulder instability.
Related Concept Videos
The Anchoring-and-Adjustment Heuristic
Anchoring Junctions
Lipids as Anchors
The carboxy-terminal of most of the prenylated proteins, such as Ras proteins, contains...
GPI Anchoring of Proteins in the ER Membrane
GPI-anchor structure
A sequence of 11 enzymatic reactions results in the synthesis of the complete GPI anchor consisting of a hydrophobic and a hydrophilic portion. The hydrophobic portion comprises phosphatidylinositol, while the hydrophilic part comprises polar groups like phosphoethanolamine,...
Tail-anchoring of Proteins in the ER Membrane
Cranial Bones: Superior and Posterior View
The frontal bone is the single bone that forms the forehead. At its anterior midline, between the eyebrows, there is a slight depression called the glabella. The frontal bone also forms the supraorbital margin of the orbit. Near the middle of this margin is the supraorbital foramen, the opening that provides passage for a sensory nerve to the forehead. The frontal bone is thickened just above each supraorbital margin,...