Related Experiment Video
Updated: Feb 4, 2026

Dynamic Navigation for Dental Implant Placement
Published on: September 13, 2022
Poly Implant Prothèse silicone breast implants: implant dynamics and capsular contracture
Y Bachour1, Z C M Heinze1, T S Dormaar2
11Department of Plastic, Reconstructive and Hand Surgery, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam, The Netherlands.
Background:
The Poly Implant Prothèse (PIP) implants were withdrawn from the market in 2010 due to the use of low-grade silicone, causing a high risk for implant rupture. The aim of this study was to investigate the implant dynamics of PIP breast implants, as well as to determine the rate and predictors of implant gel bleeding, rupture, and capsular contracture in PIP implants.
Methods:
Eighty women with a total of 152 PIP implants who underwent a reoperation in 2012 were enrolled in this study. Physical investigation included assessing the Baker score and demographics were retrospectively traced in medical records. The pre- and post-operative volumes of the implants were calculated and their state was determined intraoperatively by the surgeon.
Results:
The implants were removed after a mean implant duration of 11 ± 2.1 years. Gel bleed and implant rupture occurred in respectively 42 and 25% of the implants. Intact implants had post-operative volume increase as well as decrease. There was a correlation between gel bleeding and more post-operative implant volume increase (P ≤ 0.05). Capsular contracture had a protective effect against post-operative implant volume increase (P ≤ 0.05), while a post-operative implant volume increase provided a protective influence in developing capsular contracture (P ≤ 0.05). Additionally, implant rupture led to a higher risk of capsular contracture (P ≤ 0.05).
Conclusions:
We managed to illustrate that PIP implant shells were too permeable and that there is a correlation between gel bleeding and the increase of the post-operative implant volume. Implant rupture led to a higher risk for developing capsular contracture.Level of evidence: Level III, risk / prognostic study.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
09:59Implantation of Chronic Silicon Probes and Recording of Hippocampal Place Cells in an Enriched Treadmill Apparatus
Published on: October 11, 2017
Related Concept Videos
Dynamic Equilibrium
Equation of Rotational Dynamics
Dynamics of Circular Motion
Any acceleration must be produced by some force. Therefore, any force or combination of forces can cause centripetal acceleration. A few examples include the tension in the rope on a...
Fermi Level Dynamics
Electron affinity in semiconductors refers to the energy gap between the minimum of its conduction band and the vacuum level and it is a critical parameter in determining how easily a semiconductor can accept additional electrons.
The work...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Dynamic Modulus of Elasticity of Concrete