Related Experiment Video
Updated: Feb 4, 2026

14:14
The Innovation Arena: A Method for Comparing Innovative Problem-Solving Across Groups
Published on: May 13, 2022
6.4K
An Innovative Appliance for the Simultaneous Treatment of Premolar Space Loss and Lip Sucking Habit
Neil De Souza1, Sergio Martires2, Paul Chalakkal1
1Department of Pedodontics and Preventive Dentistry, Goa Dental College and Hospital, Bambolim, Goa, India.
Contemporary Clinical Dentistry
|October 9, 2018
Abstract:
The active lingual arch (LA) and the lip bumper (LB) are popular appliances used for maintaining or increasing arch length. This article highlights an innovative appliance that incorporates the LA and the LB, indicated for the simultaneous treatment of space loss and lip sucking habit.
Related Concept Videos
Line Loss
543
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
543
Reducing Line Loss
390
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
Space Trusses
1.3K
A space truss is a three-dimensional counterpart of a planar truss. These structures consist of members connected at their ends, often utilizing ball-and-socket joints to create a stable and versatile framework. The space truss is widely used in various construction projects due to its adaptability and capacity to withstand complex loads.
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
1.3K
State Space Representation
573
The frequency-domain technique, commonly used in analyzing and designing feedback control systems, is effective for linear, time-invariant systems. However, it falls short when dealing with nonlinear, time-varying, and multiple-input multiple-output systems. The time-domain or state-space approach addresses these limitations by utilizing state variables to construct simultaneous, first-order differential equations, known as state equations, for an nth-order system.
Consider an RLC circuit, a...
Consider an RLC circuit, a...
573
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K
Major Losses in Pipes
2.0K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K