A Device for Performing Cell Migration/Wound Healing in a 96-Well Plate
Published on: March 7, 2017
Continuous, label-free, 96-well-based determination of cell migration using confluence measurement
Christian Mayr1,2, Marlena Beyreis1,3, Heidemarie Dobias4
1a Institute of Physiology and Pathophysiology, Laboratory for Tumour Biology and Experimental Therapies (TREAT) , Paracelsus Medical University Salzburg , Salzburg , Austria.
Abstract:
Cellular migration is essential in diverse physiological and pathophysiological processes. Here, we present a protocol for quantitative analysis of migration using confluence detection allowing continuous, non-endpoint measurement with minimal hands-on time under cell incubator conditions. Applicability was tested using substances which enhance (EGF) or inhibit (cytochalasin D, ouabain) migration. Using a gap-closure assay we demonstrate that automated confluence detection monitors cellular migration in the 96-well microplate format. Quantification by % confluence, % cell free-area or % confluence in cell-free area against time, allows detailed analysis of cellular migration. The study describes a practicable approach for continuous, non-endpoint measurement of migration in 96-well microplates and for detailed data analysis, which allows for medium/high-throughput analysis of cellular migration in vitro.
Related Concept Videos
Cell Migration
Cell Migration
Cancer Cell Migration through Invadopodia
Chemotaxis and Direction of Cell Migration
Role of Myosin in Cell Migration
Myosin II is a hexamer comprising two heavy chains with globular heads and coiled-coil tails, two regulatory light chains, and two essential light chains. The ATPase sites on the myosin heads hydrolyze ATP, and the released phosphate generates the force for contraction....
Cytoskeletal Coordination in Cell Migration