Related Experiment Video
Updated: Feb 4, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Autocalibrated multiband CAIPIRINHA with through-time encoding: Proof of principle and application to cardiac tissue
Giulio Ferrazzi1, Jean Pierre Bassenge1,2, Clarissa Wink1
1Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
Purpose:
In conventional multiband (MB) CAIPIRINHA, additional reference scans are acquired to allow the separation of the excited slices. In this study, an acquisition-reconstruction technique that makes use of the MB data to calculate these reference data is presented. The method was integrated into a 2D time-resolved phase-contrast MR sequence used to assess velocities of the myocardium.
Methods:
The RF phases of the MB pulse are cycled through time so that consecutive cardiac phases can be grouped to form reference scans at a lower temporal resolution. These reference data are subsequently used to separate the original slices at the original, high temporal resolution using slice/split-slice GRAPPA algorithms. Slice separation performances are evaluated and compared with conventional methods at 3 T, and 3 different strategies for the calibration of the kernels are proposed and compared. Finally, 6 subjects were scanned to assess velocities of the myocardium.
Results:
Because the acquisition of external references is not needed, no additional breath-holds are required and the full MB acceleration could be exploited. Because the reference and MB data have the same resolution and phase structure, better slice separation was achieved when comparing the proposed technique to conventional workflows. Finally, time-resolved velocities of the myocardial tissue were successfully quantified from MB data, showing good agreement with single-band measurements.
Conclusion:
Our built-in reference method allows the full exploitation of the MB acceleration and it limits the number of breath-holds.
More Related Videos
08:41Processing of Human Cardiac Tissue Toward Extracellular Matrix Self-assembling Hydrogel for In Vitro and In Vivo Applications
Published on: December 4, 2017
09:35Preclinical Cardiac Electrophysiology Assessment by Dual Voltage and Calcium Optical Mapping of Human Organotypic Cardiac Slices
Published on: June 16, 2020
Related Concept Videos
Social Proof
Bernoulli's Principle: Applications
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
Design Example: Application of Archimedes' Principle
The volume of seawater displaced by the block is determined by first calculating the block's weight. This is done by multiplying the...
Encoding
Automatic processing involves the encoding of details like time, space, frequency, and the meaning of words, usually done without conscious...
The Uncertainty Principle
Phase Diagrams